A Microcontroller-based Instrument for Prostheses Osseointegration Measurement by Electrochemical Impedance Spectroscopy
نویسندگان
چکیده
A method based on Electrochemical Impedance Spectroscopy (EIS) for the diagnosis of prosthesis osseointegration was proposed by the Authors in previous works [1]-[2]. In this paper, the design, the implementation, and the metrological characterization of a microcontroller-based prototype conceived as a stand alone instrument to be used for in-vivo clinical applications are presented. The preliminary experimental results of laboratory evaluation are presented.
منابع مشابه
Microcontroller Based Automatic Switching Types Multi-frequency Electrical Impedance Spectroscopy(EIS) System For Early Detection of Breast Cancer
Breast Cancer is among the top five causes of cancer death and topmost cause among women worldwide. The early diagnosis through simple, non-invasive and inexpensive screening can provide great deal of aid especially for the poor people of Bangladesh. Making diagnostics measurement available to the widely geographically spread population in developing countries is a challenge which is unlikely t...
متن کاملStress Corrosion Cracking Detection of Sensitized Stainless Steel 304 in Chloride Media by Using Electrochemical Impedance Spectroscopy (EIS)
Electrochemical impedance spectroscopy (EIS) was used to detect stress corrosion cracking (SCC) in stainless steel 304 alloy exposed to an aqueous environment at 120 °C. Stainless steel 304 alloy as u-bend was tested in the solution that contains 40 weight percent of magnesium chloride. U-bended samples were prepared according to ASTM G30. EIS measurements were always performed simultaneously o...
متن کاملExperimental Characterization of an Eis-based Method for Low- Invasive Diagnosis of Prosthesis Osseointegration
A digital measurement method for lowinvasive clinical diagnosis of metallic prosthesis osseointegration was proposed. Electrical impedance spectroscopy is exploited to characterize the quality of the interface bone-prosthesis tissue. In this paper, in vitro and in vivo experimental results of the application of the proposed method to the evaluation of osseointegration of metallic implants used ...
متن کاملA study of gadolinia-doped ceria electrolyte by electrochemical impedance spectroscopy
Samples of Gd2O3-doped CeO2 (GDC) were fabricated by sintering of powder compacts. Impedance spectra were measured from 400 C to 675 C in air by electrochemical impedance spectroscopy (EIS). Above w500 C, high frequency arc was not semicircular but could be fitted with a constant phase element (CPE). Abovew625 C, high frequency arc could not be resolved due to a significant contribution from th...
متن کاملElectrochemical Impedance Spectroscopy for Investigation of Different Losses in 4-cells Short Stack with Integrated Humidifier and Water Separator
Electrochemical impedance spectroscopy (EIS) is a suitable and powerful diagnostic testing method for fuel cells (FCs) since it is non-destructive and provides useful information about FC performance and its components. In this study, for the first time, a 500W cascade type 4 cells stack with integrated humidifier, water separator and internal manifolds was designed, fabricated and tested. The ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -