A multislice real-time imaging technique is described which can provide continuous visualization of the entire left ventricle under resting and stress conditions. Three dynamically adjustable slices containing apical, mid, and base short axis views are imaged 16 times/sec (48 images/sec), with each image providing 3.12 mm resolution over a 20 cm field of view. Initial studies indicate that this technique is useful for the assessment of LV function by providing simultaneous real-time visualization of all 16 wall segments. This technique may also be used for stress LV function and, when used in conjunction with contrast agents, myocardial perfusion imaging. Magn Reson Med 45:371-375, 2001.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid evaluation of left ventricular volume and mass without breath-holding using real-time interactive cardiac magnetic resonance imaging system.

OBJECTIVES The purpose of this study was to validate cardiac measurements derived from real-time cardiac magnetic resonance imaging (MRI) as compared with well-validated conventional cine MRI. BACKGROUND Although cardiac MRI provides accurate assessment of left ventricular (LV) volume and mass, most techniques have been relatively slow and required electrocardiogram (ECG) gating over many hea...

متن کامل

Triggered real-time MRI and cardiac applications.

Real-time interactive MRI is becoming the method of choice for many cardiac applications. One current limitation of real-time techniques is inaccurate slice registration during free-breathing. A simple "triggered real-time" imaging approach is proposed which enables the acquisition of synchronized and accurately registered real-time movie loops during short breathholds. Initial in vivo results ...

متن کامل

Highly accelerated real-time cardiac cine MRI using k-t SPARSE-SENSE.

For patients with impaired breath-hold capacity and/or arrhythmias, real-time cine MRI may be more clinically useful than breath-hold cine MRI. However, commercially available real-time cine MRI methods using parallel imaging typically yield relatively poor spatio-temporal resolution due to their low image acquisition speed. We sought to achieve relatively high spatial resolution (∼2.5 × 2.5 mm...

متن کامل

Whole-heart cine MRI using real-time respiratory self-gating.

Two-dimensional (2D) breath-hold cine MRI is used to assess cardiac anatomy and function. However, this technique requires cooperation from the patient, and in some cases the scan planning is complicated. Isotropic nonangulated three-dimensional (3D) cardiac MR can overcome some of these problems because it requires minimal planning and can be reformatted in any plane. However, current methods,...

متن کامل

Rapid left ventricular function MRI with an accelerated real-time-based spiral acquisition

Background Breath-held (BH) cardiac cine MRI is a widely used technique for the assessment of cardiac left ventricular (LV) function. Image quality can be severely compromised in subjects who cannot perform the required breath holds or in subjects with arrhythmia. Additionally, the series of breath holds required for full ventricular coverage leads to prolonged exam times. These drawbacks can b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 45 3  شماره 

صفحات  -

تاریخ انتشار 2001