Comparison of Deconvolution Filters for Photoacoustic Tomography.

نویسندگان

  • Dominique Van de Sompel
  • Laura S Sasportas
  • Jesse V Jokerst
  • Sanjiv S Gambhir
چکیده

In this work, we compare the merits of three temporal data deconvolution methods for use in the filtered backprojection algorithm for photoacoustic tomography (PAT). We evaluate the standard Fourier division technique, the Wiener deconvolution filter, and a Tikhonov L-2 norm regularized matrix inversion method. Our experiments were carried out on subjects of various appearances, namely a pencil lead, two man-made phantoms, an in vivo subcutaneous mouse tumor model, and a perfused and excised mouse brain. All subjects were scanned using an imaging system with a rotatable hemispherical bowl, into which 128 ultrasound transducer elements were embedded in a spiral pattern. We characterized the frequency response of each deconvolution method, compared the final image quality achieved by each deconvolution technique, and evaluated each method's robustness to noise. The frequency response was quantified by measuring the accuracy with which each filter recovered the ideal flat frequency spectrum of an experimentally measured impulse response. Image quality under the various scenarios was quantified by computing noise versus resolution curves for a point source phantom, as well as the full width at half maximum (FWHM) and contrast-to-noise ratio (CNR) of selected image features such as dots and linear structures in additional imaging subjects. It was found that the Tikhonov filter yielded the most accurate balance of lower and higher frequency content (as measured by comparing the spectra of deconvolved impulse response signals to the ideal flat frequency spectrum), achieved a competitive image resolution and contrast-to-noise ratio, and yielded the greatest robustness to noise. While the Wiener filter achieved a similar image resolution, it tended to underrepresent the lower frequency content of the deconvolved signals, and hence of the reconstructed images after backprojection. In addition, its robustness to noise was poorer than that of the Tikhonov filter. The performance of the Fourier filter was found to be the poorest of all three methods, based on the reconstructed images' lowest resolution (blurriest appearance), generally lowest contrast-to-noise ratio, and lowest robustness to noise. Overall, the Tikhonov filter was deemed to produce the most desirable image reconstructions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Basis pursuit deconvolution for improving model-based reconstructed images in photoacoustic tomography.

The model-based image reconstruction approaches in photoacoustic tomography have a distinct advantage compared to traditional analytical methods for cases where limited data is available. These methods typically deploy Tikhonov based regularization scheme to reconstruct the initial pressure from the boundary acoustic data. The model-resolution for these cases represents the blur induced by the ...

متن کامل

Time-resolved photoacoustic spectroscopy using fiber Bragg grating acoustic transducers

An acoustic transducer based on a fiber Bragg grating (FBG) is presented and characterized for use in time-resolved laser-induced photoacoustic spectroscopy (PAS) on solid samples. The photoacoustic wave was generated by pulsed laser excitation of immobilized carbon black or erbium oxide powder, and detected by recording either the transmission or reflection spectrum of a clamped fiber Bragg gr...

متن کامل

Utilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures

Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...

متن کامل

Single-walled carbon nanotubes as a multimodal-thermoacoustic and photoacoustic-contrast agent.

We have developed a novel carbon nanotube-based contrast agent for both thermoacoustic and photoacoustic tomography. In comparison to deionized water, single-walled carbon nanotubes exhibited more than twofold signal enhancement for thermoacoustic tomography at 3 GHz. In comparison to blood, they exhibited more than sixfold signal enhancement for photoacoustic tomography at 1064 nm wavelength. ...

متن کامل

High resolution image reconstruction in ultrasound computer tomography using deconvolution

Ultrasound computer tomography is an imaging method capable of producing volume images with high spatial resolution. The imaged object is enclosed by a cylindrical array of transducers. While one transducer emits a spherical wavefront (pulse), all other transducers are recording the radiofrequency (RF) a–scans simultaneously. Then another transducer acts as the emitter and so on. In this paper ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • PloS one

دوره 11 3  شماره 

صفحات  -

تاریخ انتشار 2016