Detection of ventricular tachycardia using scanning correlation analysis.

نویسندگان

  • B M Steinhaus
  • R T Wells
  • S E Greenhut
  • S M Maas
  • T A Nappholz
  • J M Jenkins
  • L A DiCarlo
چکیده

Cross correlation is an accurate method for distinguishing normal sinus rhythm (NSR) from ventricular arrhythmias. The computational demands of the method, however, have prohibited development of an implantable device using correlation. In this study, temporal data compression prior to correlation analysis was used to reduce the total number of computations. Unipolar and bipolar intracardiac electrograms of NSR and 23 episodes of ventricular tachycardia (VT) from 23 patients were obtained from a right ventricular apex electrode catheter during routine electrophysiology studies. The data were filtered (1-11 Hz), digitized (250 samples/sec) and temporally compressed to 50 samples/sec. Data compression removed four out of every five samples by only saving the sample with the maximum excursion from the last saved sample. The average squared correlation coefficient (r2) was computed for the NSR and VT episodes using each patient's NSR waveform as a template. In all 23 patients, the r2 values showed large separation between NSR versus VT in both unipolar (0.93 +/- 0.05 vs 0.20 +/- 0.16, P less than 0.005) and bipolar (0.91 +/- 0.07 vs 0.17 +/- 0.11, P less than 0.005) electrode configurations using template lengths of 80% the intrinsic interval (avg +/- SD). Narrow templates (40% intrinsic interval or less) often resulted in multiple r2 peaks during each heart cycle and degraded the r2 separation (n = 10, P less than 0.005). High pass filtering at 3 Hz also degraded the r2 separation (n = 10, P less than 0.05). Standard noncompressed correlations indicated that data compression had negligible effects on the results. Thus, a computationally efficient cross correlation method was found to be a reliable detector of VT.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Identification of ventricular tachycardia using intracardiac electrograms: a comparison of unipolar versus bipolar waveform analysis.

Implantable antitachycardia devices suffer a high false-positive rate of delivery of therapy because current detection schemes based upon ventricular rate and rate variations are excessively sensitive at the cost of specificity. Several methods have been proposed for providing complementary information derived from morphologic analysis of intraventricular electrograms in order to increase speci...

متن کامل

Identification of Ventricular Tachycardia Using Intracavitary Ventricular Electrogralfls: - Analysis of Time and Frequency Domain Patterns

LIN, D., ET AL.: Identification of ventricular tachycardia using intracavitary ventricular electrograms: analysis of time and frequency domain patterns. Tachycardia detection by impladtable antitachycardia devices using rate alone has major limitations. Several alternative methods have bden proposed to distinguish ventricular tachycardia or ventricular fibrillation from normal sinus rhythm usin...

متن کامل

Identification of ventricular tachycardia using intracavitary ventricular electrograms: analysis of time and frequency domain patterns.

Tachycardia detection by implantable antitachycardia devices using rate alone has major limitations. Several alternative methods have been proposed to distinguish ventricular tachycardia or ventricular fibrillation from normal sinus rhythm using intracardiac electrograms. These methods have not been tested, however, for recognition of ventricular tachycardia in patients with abnormal surface QR...

متن کامل

Ventricular tachycardia detection using bipolar electrogram analysis is site specific.

While algorithms for bipolar intraventricular electrogram analysis have potential use in complementing rate criteria for ventricular tachycardia (VT) detection by implantable antitachycardia devices, the sensitivity of such algorithms to the intracavitary site of electrogram detection has not been determined. In this study, unfiltered (1-500 Hz) electrograms were recorded from a bipolar electro...

متن کامل

A new approach to detect Life threatening cardiac arrhythmias using Sequential spectrum of Electrocardiogram signals

This study evaluates the discriminative power of sequential spectrum analysis of the short-term electrocardiogram (ECG) time series in separating normal and subjects with life threatening arrhythmias like, ventricular tachycardia/fibrillation (VT/VF). The raw ECG time series is transformed into a series of binary symbols and the binary occupancy or relative distribution of mono-sequences (i.e. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Pacing and clinical electrophysiology : PACE

دوره 13 12 Pt 2  شماره 

صفحات  -

تاریخ انتشار 1990