Fresh gas requirements of an enclosed afferent reservoir breathing system in anaesthetized, spontaneously breathing adults.

نویسندگان

  • J R Barrie
  • P C Beatty
  • I T Campbell
  • G Meakin
  • T E Healy
چکیده

Using two methods of determining the onset of rebreathing, we have determined the minimum fresh gas flow rate (VF) of the Ohmeda enclosed afferent reservoir breathing system (EAR) in anaesthetized, spontaneously breathing adults. Rebreathing as defined by the Kain and Nunn criteria did not occur when the VF/VE ratio was greater than 0.70. A mathematical model was used to calculate the degree of rebreathing at each VF. From this model, rebreathing did not occur when VF was 0.86 VE or more and this value of VF/VE is considered appropriate to eliminate rebreathing in clinical practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fresh gas requirements of an enclosed afferent reservoir breathing system during controlled ventilation in children.

An enclosed afferent reservoir breathing system (EAR) designed by Ohmeda was evaluated during anaesthesia with controlled ventilation in 104 healthy children. Carbon dioxide production and arterial carbon dioxide tension were measured in 12 children in order to determine the proportion of fresh gas (VF) involved in gas exchange. When the ratio of minute volume ventilation to fresh gas flow (VE:...

متن کامل

Efficiency of an enclosed afferent reservoir breathing system during controlled ventilation.

We describe an enclosed afferent reservoir (EAR) breathing system developed by Ohmeda and designed to operate efficiently in spontaneous and controlled ventilation. The efficiency of the system was evaluated by calculating the fractional utilization of fresh gas in 10 ASA I-III patients during anaesthesia with controlled ventilation. Maximum efficiency occurred when the minute ventilation to fr...

متن کامل

Enclosed afferent reservoir breathing systems. Description and clinical evaluation.

A new group of breathing systems, namely the Enclosed Afferent Reservoir (EAR) systems, is described. They allow for the selective elimination of alveolar gas in association with both spontaneous and controlled ventilation. A comparison with the Bain system in controlled ventilation demonstrates greater efficiency in eliminating carbon dioxide. A fresh gas flow (VF) of 70 ml kg-1 min-1 using an...

متن کامل

Baby EAR circuit: a clinical determination of optimal fresh gas flow in spontaneous breathing anesthesia.

BACKGROUND Baby EAR circuit is a new modified enclosed afferent reservoir anesthetic breathing system invented to use in pediatric patients. By following His Majesty the King of Thailand's self-sufficiency philosophy, the circuit is simplymade of low-cost and easy-to-find materials in the operating room. OBJECTIVE Investigate clinical use of the circuit and to find the optimal fresh gas flow ...

متن کامل

Imposed work of breathing during high-frequency oscillatory ventilation: a bench study

INTRODUCTION The ventilator and the endotracheal tube impose additional workload in mechanically ventilated patients breathing spontaneously. The total work of breathing (WOB) includes elastic and resistive work. In a bench test we assessed the imposed WOB using 3100 A/3100 B SensorMedics high-frequency oscillatory ventilators. METHODS A computer-controlled piston-driven test lung was used to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 70 4  شماره 

صفحات  -

تاریخ انتشار 1993