More Tests with a Variable Ramp Intake having a Design Mach Number of 2.2

نویسنده

  • M. C. Neale
چکیده

SUMMARY Results are repvted of tests on a two-dimensional combined external/internal compressIon Intake having a design Mach number of 2.2. The particular parameters investigated in the tests now reported are:-(a) sidewall bleed, (b) a 3 to 1 range of free stream Reynolds number, (cl the length of subsonic diffuser, Cd) sidewalls out back to the line of the second ramp shock. The maximum pressure recovery obtained at the design Mach number was 90.9 per cent with 6.4 per cent bleed. A better performance was a pressure recovery of 90 per cent with only 3.4 per cent bleed. These fz@res were obtained at a Reynolds number, based on free stream conditions and intake capture heqht of 3.25 x 10". It seems possible that these pressure recoveries may be close to the maxunum attainable at Mach 2.2 in a mixed compression xntake of acceptable mechanical complexity, and employing a sunple four shock system.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Some Tests with a Variable Ramp Intake having Sidewall Compression and a Design

Results are reported of some-tests aimed at determinmg the effect of sidewall compresslon III a " two-dimensional " lntslce having combined external/internal compression and a design Mach number of 2.2. Sidewall oompresslon results from the chamfers that are necessary to provide thickness for the splitter plate separatmng the two units of a twin cell intake. The results suggest that the maximum...

متن کامل

Tests with a Two-dimensional Intake having All-external Compression and a Design Mach Number of 2.0 BY

Results are reported of teats on a two-dimensional external com-presslon intake having a design Mach number of 2.0. A pressure rccovory of 93 per cent was measured with 3.3 per cent bleed from the ramp surface at the throat. The introduotlon of a small contractlon in the throat unproved the stable sub-crltlcal margin of the u&&e. The test Reynolds number based on free stream oondltions and Inta...

متن کامل

Measurement of the Internal Performance of a Rfxtanglilar Air Intake with Variable Geometry at Mach Numbers

SUMMARY Measurements have been made of the internal performance of a rectangular intake having variable geometry compression surfaces. The measurements have been made over a range of Mach numbers from 1.70 to 2.46. The Reynolds number based on intake height was between 1.27 and 1.54 x 106. Pressure recoveries at zero bleed are well below those predlcted from simple shock patterns, but there is ...

متن کامل

One-Dimensional design of a three-stage axial compressor with Its 3D numerical simulation

The purpose of this study is to design a three-stage axial compressor with identical pressure ratio which makes an adequate pressure ratio and efficiency in design point conditions with rotational velocity of 38000rpm and mass flow rate of 3.2kg/s. First of all, considering some restrictions such as Dehaller number more than 0.7 in all sections of the stator and the rotor, and relative Mach num...

متن کامل

Tests at a Mach Number of 2-O on a Rectangular, Twin-Duct Air Intake with Variable Geometry, Situated in the Flow Field of a Slender Wing

r SUMMARY The tests were made in the jft x jft tunnel to assess the performance of a rectangular twin-duct intake, including effeots of limited immersion of the intake xnto a wing boundary layer. The effects in one duct, arising from interference caused by varying the flow through the other, have slso been mvestigated. Partial immersion of the lntske into the wing boundary layer causes little d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -