The reliability of side to side measurements of upper extremity activity levels in healthy subjects
نویسندگان
چکیده
BACKGROUND In both clinical and occupational settings, ambulatory sensors are becoming common for assessing all day measurements of arm motion. In order for the motion of a healthy, contralateral side to be used as a control for the involved side, the inherent side to side differences in arm usage must be minimal. The goal of the present study was to determine the reliability of side to side measurements of upper extremity activity levels in healthy subjects. METHODS Thirty two subjects with no upper extremity pathologies were studied. Each subject wore a triaxial accelerometer on both arms for three and a half hours. Motion was assessed using parameters previously reported in the literature. Side to side differences were compared with the intraclass correlation coefficient, standard error of the mean, minimal detectable change scores and a projected sample size analysis. RESULTS The variables were ranked based on their percentage of minimal detectable change scores and sample sizes needed for paired t-tests. The order of these rankings was found to be identical and the top ranked parameters were activity counts per hour (MDC% = 9.5, n = 5), jerk time (MDC% = 15.8, n = 8) and percent time above 30 degrees (MDC% = 34.7, n = 9). CONCLUSIONS In general, the mean activity levels during daily activities were very similar between dominant and non-dominant arms. Specifically, activity counts per hour, jerk time, and percent time above 30 degrees were found to be the variables most likely to reveal significant difference or changes in both individuals and groups of subjects. The use of ambulatory measurements of upper extremity activity has very broad uses for occupational assessments, musculoskeletal injuries of the shoulder, elbow, wrist and hand as well as neurological pathologies.
منابع مشابه
Intra-rater reliability of sonographic measurement of the upper trapezius, supraspinatus and deltoid muscles in women with frozen shoulder and healthy women
Background: Some studies show that frozen shoulder is due to the pathologic changes in the muscles around the shoulder. Measurement of the ultrasonic thickness of a muscle is a method for measuring the muscle changes. There is no study about the reliability of measurement of the muscle’s ultrasonic thickness around the shoulder in patients with frozen shoulder. The present study aims to invest...
متن کاملProximity of Vital Structures to the Clavicle: Comparison of Fractured and Non-fractured Side
Background: Previous anatomic and radiological studies have described the relationship of the clavicle to major neurovascular structures in healthy subjects. We were curious about this relationship in patients with a clavicle fracture and if it is different from non-fractured clavicles. Methods: We retrospectively identified all patients with a clavicle fracture between July 2001 and Octobe...
متن کاملComparison of upper extremity function, pain, and tactile sense between the uneffected side of hemiparetic patients and healthy subjects
[Purpose] The aim of this study was to compare the unaffected upper extremity of patients with hemiparesis with that of healthy subjects in terms of function, pain, and tactile sense. [Subjects and Methods] Upper extremity evaluation parameters of 20 patients with hemiparesis were compared with an age-matched control group of 20 healthy subjects. A shorter version of the Disability of Arm and S...
متن کاملبررسی تکرارپذیری نیروی عکس العمل زمین حین استفاده از ابزار اعمال اغتشاش اندام تحتانی در حرکت ایستادن روی یک پا
Introduction: The aim of the current study was to measure ground reaction force and center of pressure (COP) during lower extremity perturbation in single leg standing whit knee flexion and extension in healthy subjects, in addition to revealing reliability of the device used for the related perturbation for using another studies, reliability is one of the characteristic of measuring instrumen...
متن کاملApplications of diffusion weighted imaging in detection of radiating pain to lower extremities
Introduction: To examine the hypothesis that diffusion weighted imaging (DWI) in lumbosacral region could reveal sciatic nerve course swelling that lead to lower extremity pain. The aim of present article was to find and evaluate the diffusion weighted coefficients (b-values) for scrutinizing sciatic nerve tract changes in lumbosacral region. Materials and methods: Lumbar area was imaged in 30...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 11 شماره
صفحات -
تاریخ انتشار 2010