Adaptation and focusing of optode configurations for fluorescence optical tomography by experimental design methods.

نویسندگان

  • Manuel Freiberger
  • Christian Clason
  • Hermann Scharfetter
چکیده

Fluorescence tomography excites a fluorophore inside a sample by light sources on the surface. From boundary measurements of the fluorescent light, the distribution of the fluorophore is reconstructed. The optode placement determines the quality of the reconstructions in terms of, e.g., resolution and contrast-to-noise ratio. We address the adaptation of the measurement setup. The redundancy of the measurements is chosen as a quality criterion for the optodes and is computed from the Jacobian of the mathematical formulation of light propagation. The algorithm finds a subset with minimum redundancy in the measurements from a feasible pool of optodes. This allows biasing the design in order to favor reconstruction results inside a given region. Two different variations of the algorithm, based on geometric and arithmetic averaging, are compared. Both deliver similar optode configurations. The arithmetic averaging is slightly more stable, whereas the geometric averaging approach shows a better conditioning of the sensitivity matrix and mathematically corresponds more closely with entropy optimization. Adapted illumination and detector patterns are presented for an initial set of 96 optodes placed on a cylinder with focusing on different regions. Examples for the attenuation of fluorophore signals from regions outside the focus are given.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optode positional calibration in diffuse optical tomography.

Although diffuse optical tomography is a highly promising technique used to noninvasively image blood volume and oxygenation, the reconstructed data are sensitive to systemic difference between the forward model and the actual experimental conditions. In particular, small changes in optode location or in the optode-tissue coupling coefficient significantly degrade the quality of the reconstruct...

متن کامل

Design novel optical sensor for determination of bismuth based on immobilization of 4-(4-nitrophenyl)-1-naphthol on a triacetylcellulose membrane

A novel optical sensor has been proposed for sensitive determination of bismuth ion basedon immobilization of 4-(4-nitrophenylazo)-1-naphthol on a triacetylcellulose membrane.Chemical binding of bismuth ions in solution with a 4-(4-nitrophenylazo)-1-naphtholimmobilized on the triacetylcelluse surface could be monitored spectrophotometrically. Theoptode shows excellent response over wide concent...

متن کامل

Design and Evaluation of a Mercury (II) Optode Based on Immobilization of 5, 6 Di methyl -1- (4 methyl benzyl) -2- para tolyl-1H-benzimidazole (DMBPTBI) on a Triacetylcellulose Membrane and Determination in Various Samples

The characterization of an optical sensor membrane is described for the determination of Hg2+ ions based on the immobilization of 5, 6 Di methyl -1- ( 4 methyl benzyl) -2- para tolyl-1H-benzimidazole (DMBPTBI) on a triacetylcellulose membrane. The membrane responds to mercury ions by changing color reversibly from orange to red in universal buffer solution at pH 2. Under optimum conditions, the...

متن کامل

A deterministic approach to the adapted optode placement for illumination of highly scattering tissue

A novel approach is presented for computing optode placements that are adapted to specific geometries and tissue characteristics, e.g., in optical tomography and photodynamic cancer therapy. The method is based on optimal control techniques together with a sparsity-promoting penalty that favors pointwise solutions, yielding both locations and magnitudes of light sources. In contrast to current ...

متن کامل

Reduction of image artifacts induced by change in the optode coupling in time-resolved diffuse optical tomography.

Tomographic images of the optical properties can be reconstructed using inversion algorithms for diffuse optical tomography (DOT); however, changes in the optode coupling that occurs while obtaining an object's measurements may often lead to the presence of artifacts in the reconstructed images. To reduce the number of artifacts induced by optode coupling, previous studies have introduced (unkn...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 15 1  شماره 

صفحات  -

تاریخ انتشار 2010