Routine chest radiography after permanent pacemaker implantation: is it necessary?
نویسندگان
چکیده
BACKGROUND AND AIMS Chest radiographs (CXRs) are performed routinely after permanent pacemaker implantation to identify pacemaker lead position and exclude pneumothorax. We assessed the clinical value and need for this procedure. DESIGN Retrospective analysis of pacemaker data and CXRs following permanent pacemaker insertion between December 2002 and February 2004. MATERIALS AND METHODS Post-procedural CXRs were available in 125/126 consecutive patients after either first endocardial pacemaker implantation or insertion of at least one new lead. Subclavian vein puncture was used for venous access in all cases. CXRs were examined to establish the incidence of pneumothorax and assess pacing lead positions. The clinical records were examined in all patients who had subsequent CXRs or a further pacemaker procedure to identify the indication for these and to establish whether CXR had influenced patient management. RESULTS In total, 192 post-procedural CXRs were performed, either postero-anterior (PA) and/or lateral views. Ventricular and/or atrial pacing lead contour and electrode position was considered radiographically appropriate in 86% CXRs. Fourteen per cent of post-procedural radiographs were considered to have radiologically sub-optimal pacemaker lead positioning. None of the patients with these "abnormal" radiographs experienced subsequent pacemaker complications or had further radiographs recorded at a later date. Later repeat CXRs were performed in 16 patients (13%) but only 3 patients (2%) had pacing abnormalities as the primary indication. All three had satisfactory pacing lead position on initial post-implantation and later radiographs, but required further procedures for lead re-positioning. Iatrogenic pneumothorax occurred in one patient (incidence 0.8%) in our series. CXR confirmed the clinical diagnosis and allowed an assessment of size to guide treatment. CONCLUSION Routine CXR after permanent pacemaker insertion is not necessary in uncomplicated cases with adequate pacing characteristics.
منابع مشابه
An Unusual Case of Embolic Stroke: A Permanent Ventricular Pacemaker Lead Entirely Within the Arterial System Documented by Transthoracic and Transesophageal Echocardiography.
A pacemaker lead in the left ventricle is a rare complication of implantation. Recognition of this complication is important because thromboembolic events are associated. We report the first case, to our knowledge, of a patient who had a permanent pacemaker implanted via the left subclavian artery to the left ventricle, which is documented by electrocardiography, chest radiography, thoracic ech...
متن کاملPacemaker Twiddler's Syndrome
A 76-yr-old man with unipolar ventricular pacemaker, previously implanted in the right ventricular apex, presented with syncopal attack and twitching of the right pectoralis muscle. He finally was diagnosed as having Twiddler's syndrome. The patient had a pulse rate of 36/min and cannon waves in the neck veins. Chest radiography showed a dislodged pacing lead completely wrapped around the pulse...
متن کاملSick sinus syndrome requiring permanent pacemaker implantation in a patient with mirror-image dextrocardia.
A patient with the sick sinus syndrome accompanying mirror-image dextrocardia which was associated with double superior venae cavae and an absent inferior vena cava is presented. A permanent transvenous demand pacemaker was inserted because of repeated episodes of dizziness and a documented 31/2-second period of asystole. Precise knowledge of the venous system and the location of the apex of th...
متن کاملSuccessful perinatal management of a very low birthweight infant with congenital complete atrioventricular block.
We report a very low birthweight infant with congenital complete atrioventricular block (CCAVB) who underwent delayed implantation of a permanent pacemaker without temporary pacing. The female infant was born at 30 weeks gestation and weighed 1422 g. After birth, the infant showed respiratory failure due to pleural effusion and respiratory distress syndrome at birth. The heart rate ranged betwe...
متن کاملInadvertent malposition of a permanent pacemaker ventricular lead into the left ventricle which was initially missed and diagnosed two years later: a case report
INTRODUCTION Inadvertent malposition of a pacemaker ventricular lead into the left ventricle is an uncommon event, and its actual incidence is probably unknown. It may be underestimated and underreported because of a possible asymptomatic course. A 12-lead electrocardiogram is important to confirm proper placement. CASE PRESENTATION We report a case of a 60-year-old Caucasian man with a malpo...