Technetium-99m Methylene Diphosphonate Single-photon Emission Computed Tomography/Computed Tomography of the Foot and Ankle
نویسندگان
چکیده
The complex anatomy and function of the foot and ankle can make it difficult to determine the cause of symptoms in patients with foot and ankle pathology. Following initial clinical and radiographic assessment, additional imaging with magnetic resonance imaging may be required, which is often seen as the modality of choice. Although sensitive to pathological changes in bone metabolism and vascularity, technetium-99m (Tc-99m) bone scintigraphy often lacks the specificity and resolution required to evaluate the structures of the foot and ankle. Tc-99m methylene diphosphonate single-photon emission computed tomography/computed tomography (SPECT/CT) combines this sensitivity with the superior anatomical detail of CT, enabling better localization of pathological uptake and evaluation of associated structural changes. As a result, SPECT/CT has been growing in popularity for the assessment of patients with foot and ankle pathology where it can provide additional information that may change the initial diagnosis and subsequent management plan. Studies have reported modification of the surgical approach and site of intra-articular local anesthetic injections following SPECT/CT with good results. Interpretation of SPECT/CT studies requires an understanding of the pathological changes that result in increased tracer accumulation in addition to the CT changes that may be seen. This review aims to highlight the advantages of SPECT/CT, potential applications and explain the imaging appearances of common pathologies that may be observed.
منابع مشابه
Utilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures
Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...
متن کاملIncreased 99 mTc MDP activity in the costovertebral and costotransverse joints on SPECT - CT : is it predictive of associated back pain or response to percutaneous treatment ? MUSCULOSKELETAL IMAGING
PURPOSE Pain related to costovertebral and costotransverse joints is likely an underrecognized and potentially important cause of thoracic back pain. On combined single-photon emission computed tomography and computed tomography (SPECT-CT), increased technetium-99m methylene diphosphonate (99mTc MDP) activity at these articulations is not uncommon. We evaluated whether this activity corresponds...
متن کاملEvaluation of mandibular invasion by head and neck cancers using 99mTc-methylene diphosphonate or 99mTc-hydroxymethylene diphosphonate and 201Tl chloride dual isotope single photon emission computed tomography.
Whether a patient with head and neck cancer has mandibular invasion or not is important in determining the method of resection surgery. But, no modality is adequately reliable when used alone in the evaluation of mandibular invasion. Therefore, to more accurately diagnose mandibular invasion in head and neck cancer, we used a new modality, namely, 99mTc methylene diphosphonate (MDP) or 99mTc hy...
متن کاملSUV measurement of normal vertebrae using SPECT/CT with Tc-99m methylene diphosphonate.
The purpose of this study is to perform quantitative measurement based on the standardized uptake value (SUV) of the uptake of Tc-99m methylene diphosphonate (MDP) in the normal vertebrae using a single photon emission tomography (SPECT)/computed tomography (CT) scanner. A retrospective study of patients with cancer or joint disorders was performed. We acquired data for a group of 29 patients (...
متن کاملSPECT-CT for characterization of extraosseous uptake of 99mTc-methylene diphosphonate on bone scintigraphy.
Bone scintigraphy is a sensitive and popular method for imaging a wide array of benign or malignant skeletal abnormalities. However, the uptake of tracers used for bone scintigraphy may be observed in various extraosseous sites, thereby limiting its specificity. It is difficult to correctly localize such sites of uptake on planar bone scintigraphy alone. The addition of hybrid single-photon emi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 16 شماره
صفحات -
تاریخ انتشار 2017