Delayed pericardial effusion due to perforation of the right ventricular outflow tract by an ICD lead.
نویسندگان
چکیده
A delayed pericardial effusion developed in a recipient of a cardioverter defibrillator (ICD). After an uneventful implant procedure and postoperative recovery, the patient suffered loss of appetite and fatigue, and was re-admitted to the hospital 48 days later. Her vital signs were stable and cardiac silhouette on chest roentgenogram was normal. However, blood cell counts and chemistry revealed the presence of anemia and liver dysfunction, an echocardiogram showed a diffuse pericardial effusion, and computed tomography suggested that the ICD lead, screwed in the right ventricular outflow tract, had perforated the wall. In order to make a prompt diagnosis and initiate timely corrective treatment, the physician in charge of long-term follow-up should remember that a pericardial effusion can be delayed and accumulate in the absence of typical signs of cardiac tamponade after ICD lead implantation.
منابع مشابه
Delayed Perforation of the Right Ventricular Wall by a Single Standard-Caliber Implantable Cardioverter-Defibrillator Lead Detected by Multidetector Computed Tomography
We present an unusual case of a delayed right ventricular perforation by a single standard-caliber implantable cardioverter-defibrillator lead, which manifested 14 days after implantation. Multidetector computed tomography could clearly display the lead perforation, and allow for identification of the associated sequelae such as pericardial effusion and planning the lead extraction strategy.
متن کاملSurgical Repair of Subacute Right Ventricular Perforation after Pacemaker Implantation
We report an 84-year-old woman who presented with right ventricular perforation 4 days after pacemaker implantation for syncope due to sick sinus syndrome. Median sternotomy revealed no pericardial effusion, but the pacing lead had penetrated the right ventricle and pericardium. When the pleura was opened, the tip of the lead was seen in the visceral pleura. The lead was cut in the pericardial ...
متن کاملImages in cardiovascular medicine. Left ventricular outflow tract obstruction caused by tamponade.
A transthoracic echocardiogram of a 72-year-old woman who was admitted to the hospital complaining of dyspnea at rest and peripheral edema showed severe pericardial effusion with right chamber and left atrial collapse, as well as left ventricular hypertrophy with systolic anterior movement of the septal mitral leaflet and systolic gradient through the left ventricular outflow tract (peak gradie...
متن کاملCardiac Perforation Associated with a Pacemaker or ICD Lead
Cardiac perforation after pacemaker or implantable cardioverter-defibrillator (ICD) implantation is an infrequent complication. The reported rates of perforation are 0.1-0.8% after pacemaker implantation and 0.6-5.2% after ICD implantation (Khan et al., 2005; Mahapatra et al., 2005). From 1994 to 2009, total 1026 permanent pacemakers and ICDs were implanted in my lab, and two cases (0.2%) devel...
متن کاملCardiac tamponade from compression of the pulmonary arterial outflow graft of a biventricular assist device.
A 19-year-old patient with a Thoratec Paracorporeal Biventricular Assist Device implanted 15 weeks previously complained of discomfort in his back and chest area, lightheadedness, and diaphoresis, and was noted to have a blood pressure of 62/26 mm Hg. Device alarms sounded for both the left and right ventricular assist devices indicating that the paracorporeal pumps were not filling normally. A...