Doppler color flow "proximal isovelocity surface area" method for estimating volume flow rate: effects of orifice shape and machine factors.
نویسندگان
چکیده
Previously described Doppler color flow mapping methods for estimating the severity of valvular regurgitation have focused on the distal jet. In this study, a newer Doppler color flow technique, focusing on the flow proximal to an orifice, was used. This method identifies a proximal isovelocity surface area (PISA) by displaying an aliasing interface. Volume flow rate (cm3/s) can be calculated as PISA (cm2) x aliasing velocity (cm/s). For planar circular orifices, a hemi-elliptic model accurately approximated the shape of PISA. Clinically, however, orifice shapes may be noncircular. In vitro flow experiments (n = 226) using orifices of various shapes (ellipse, square, triangle, star, rectangle) were performed. Volume flow rate calculated using a hemi-elliptic model for PISA was accurate, with average percent differences from actual flow rate = +4.3% for a square, -4.2% for a triangle, -4.7% for a star, -4.5% for an ellipse and -2.8% for a rectangle. However, average percent differences for calculated volume flow rates using a hemispheric model for PISA shape ranged from -11.6% (square) to -34.8% (rectangle). In addition, to evaluate whether PISA is influenced by machine factors, in vitro studies (n = 83) were performed.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Quantification of chronic functional mitral regurgitation by automated 3-dimensional peak and integrated proximal isovelocity surface area and stroke volume techniques using real-time 3-dimensional volume color Doppler echocardiography: in vitro and clinical validation.
BACKGROUND The aim of this study was to test the accuracy of an automated 3-dimensional (3D) proximal isovelocity surface area (PISA) (in vitro and patients) and stroke volume technique (patients) to assess mitral regurgitation (MR) severity using real-time volume color flow Doppler transthoracic echocardiography. METHODS AND RESULTS Using an in vitro model of MR, the effective regurgitant or...
متن کاملCurrent status of flow convergence for clinical applications: is it a leaning tower of "PISA"?
Spatial appreciation of flow velocities using Doppler color flow mapping has led to quantitative evaluation of the zone of flow convergence proximal to a regurgitant orifice. Based on the theory of conservation of mass, geometric analysis, assuming a series of hemispheric shells of increasing velocity as flow converges on the orifice--the so-called proximal isovelocity surface area (PISA) effec...
متن کاملA new method for quantification of regurgitant flow rate using color Doppler flow imaging of the flow convergence region proximal to a discrete orifice. An in vitro study.
While color Doppler flow mapping has yielded a quick and relatively sensitive method for visualizing the turbulent jets generated in valvular insufficiency, quantification of the degree of valvular insufficiency has been limited by the dependence of visualization of turbulent jets on hemodynamic as well as instrument-related factors. Color Doppler flow imaging, however, does have the capability...
متن کاملQuantitative, noninvasive assessment of patent ductus arteriosus shunt flow by measuring proximal isovelocity surface area on color Doppler imaging.
BACKGROUND We evaluated the hemodynamic status of patent ductus arteriosus (PDA) by measuring vena contracta width (VCW) and effective shunt orifice area (ESOA) using proximal isovelocity surface area (PISA) on color Doppler imaging. METHODS AND RESULTS: Study subjects were 21 patients with PDA (mean age, 3.6 years). We measured VCW (mm/m(2)) and ESOA (cm(2)) by the PISA method using echocardio...
متن کاملApplication of color Doppler flow mapping to calculate orifice area of St Jude mitral valve.
BACKGROUND The effective orifice area (EOA) of a prosthetic valve is superior to transvalvular gradients as a measure of valve function, but measurement of mitral prosthesis EOA has not been reliable. METHODS AND RESULTS In vitro flow across St Jude valves was calculated by hemispheric proximal isovelocity surface area (PISA) and segment-of-spheroid (SOS) methods. For steady and pulsatile con...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the American College of Cardiology
دوره 17 5 شماره
صفحات -
تاریخ انتشار 1991