Immunoturbidimetric method for routine determinations of apolipoproteins A-I and B.

نویسندگان

  • D Brustolin
  • M Maierna
  • F Aguzzi
  • F Zoppi
  • G Tarenghi
  • G Berti
چکیده

A simple immunoturbidimetric method for quantifying apolipoproteins (apo) A-I and B in serum or plasma is described. A special reagent formulation, including large amounts of suitable detergents, obviates the need for a sample blank even with grossly lipemic specimens. The assay is rapid, easily automated, and thus convenient for routine work. For both apo A-I and apo B, the assay range is about 0.2-3.5 g/L. The performance characteristics were assessed with discrete (Optimate and Olli CD) and centrifugal analyzers (Cobas Fara and IL Monarch 2000). Average analytical recovery was 101.5% for apo A-I and 99.4% for apo B. Dilution tests showed found/expected ratios of 101.2% (apo A-I) and 101.0% (apo B). Overall precision (CV) ranged from 1.4% to 3.3% for apo A-I and from 1.1% to 8.3% for apo B. Comparisons with commercially available rate nephelometry, radial immunodiffusion, and immunoturbidimetric methods gave good correlations (r greater than or equal to 0.938). Using the immunoturbidimetric method, we also established the relationships between apolipoproteins and lipids and determined the reference intervals. We conclude that the proposed method is suitable for routine use in clinical laboratories.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immunoturbidimetric method for routine determinations of apolipoproteins A-I, A-II, and B in normo- and hyperlipemic sera compared with immunonephelometry.

We describe a method for routine immunoturbidimetry of apolipoproteins (apo) A-I, A-II, and B in both normo- and hyperlipemic sera. A special antiserum reagent, consisting of a highly concentrated mixture of nonionic and anionic detergents (final concentration in the assay, 36 g/L), rapidly removes intrinsic turbidities of even strongly lipemic sera without interfering with the antigen-antibody...

متن کامل

Concentration dependencies of immunoturbidimetric dose-response curves: immunoturbidimetric titer and reactivity, and relevance to design of turbidimetric immunoassays.

To characterize polyclonal antisera for two-point immunoturbidimetric applications, we defined, as functions of antiserum concentration, two parameters derived from dose-response curves: the maximum bichromatic optical response, Tmax, and the antigen concentration in the region of excess antibody corresponding to one-half Tmax, or C50. We raised monospecific polyclonal antisera in goats against...

متن کامل

Effect of plasma triglyceride concentrations on the accuracy of immunoturbidimetric assays of apolipoprotein B.

We have studied the influence of triglyceride-rich particles on the analytical bias of apolipoprotein B measurements by various immunoturbidimetric methods. Three commercially available methods grossly overestimate apolipoprotein B in samples with even moderately above-normal triglyceride concentrations. This effect is due to the increased relative reactivity of very-low-density lipoproteins in...

متن کامل

Immunoturbidimetric assays for serum apolipoproteins A1 and B using Cobas Bio centrifugal analyser.

Immunoturbidimetric assays for measuring the apolipoproteins A1 and B using the Cobas Bio centrifugal analyser are described. The methods were specific, offered good sensitivity (less than 0.05 g/l) and intrabatch variability, with coefficients of variation between 2.4% and 3.5%, and were cost effective. Reference ranges were calculated for a group of civil servants, aged 35 to 55 years.

متن کامل

Early diagnosis of acute myocardial infarction by a newly developed rapid immunoturbidimetric assay for myoglobin.

OBJECTIVE To evaluate a rapid immunoturbidimetric assay for myoglobin and to investigate its clinical usefulness in the early detection of acute myocardial infarction. DESIGN Prospective study. Immunoturbidimetrically determined myoglobin concentrations were compared with radioimmunoassay results obtained with the same blood samples. The diagnostic performance of myoglobin determination was c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 37 5  شماره 

صفحات  -

تاریخ انتشار 1991