Fluoroscopic screening of asymptomatic patients implanted with the recalled Riata lead family.

نویسندگان

  • Jeffrey Liu
  • Rohit Rattan
  • Evan Adelstein
  • William Barrington
  • Raveen Bazaz
  • Susan Brode
  • Sandeep Jain
  • G Stuart Mendenhall
  • Jan Nemec
  • Eathar Razak
  • Alaa Shalaby
  • David Schwartzman
  • Andrew Voigt
  • Norman C Wang
  • Samir Saba
چکیده

BACKGROUND The Food and Drug Administration recently issued a class I recall of the St. Jude Medical Riata implantable cardioverter-defibrillator lead presumably because of increased risk of electric failure and mechanical separation via inside-out abrasion. We sought to examine the incidence and time dependence of inside-out abrasion in asymptomatic patients implanted with the Riata lead. METHODS AND RESULTS Asymptomatic patients implanted with the Riata lead at our institution were offered voluntary fluoroscopic screening in 3 views. Electric testing of the Riata lead with provocative isometric muscle contraction was performed at the time of fluoroscopic screening. Of the 245 patients undergoing fluoroscopic screening, 53 (21.6%) patients showed clear evidence of lead separation. Of these externalized leads, 0%, 13%, and 26% had a dwell time of <3 years, 3 to 5 years, and >5 years, respectively (P=0.037). Externalized leads had a significantly pronounced decrease in R-wave amplitude (-1.7±2.9 mV versus +0.35±2.5 mV; P<0.001), and more patients with externalized leads had ≥25% decrease in R-wave amplitude from baseline (28.0% versus 8.1%; P=0.018). One patient with externalization exhibited new noise on near-field electrogram. CONCLUSIONS The Riata lead exhibits time-dependent high rates of cable externalization exceeding 20% at >5 years of dwell time. Externalized leads are associated with a more pronounced decrease in R-wave amplitude, which may be an early marker of future electric failure. The use of fluoroscopic and electric screening of asymptomatic patients with the Riata lead remains controversial in the management of patients affected by the recent Food and Drug Administration recall.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fluoroscopic investigation of Riata® transvenous defibrillator leads.

BACKGROUND Implantable cardioverter-defibrillator leads from Riata® family (St. Jude Medical Inc., Sylmar, CA, USA) have been recently recalled by Food and Drug Administration for concerns of a unique type of "inside-out" insulation failure leading to conductor externalization. The objective of this study was to evaluate the prevalence and predictors of conductor externalization in patients imp...

متن کامل

Prevalence and presentation of externalized conductors and electrical abnormalities in Riata defibrillator leads after fluoroscopic screening: report from the Netherlands Heart Rhythm Association Device Advisory Committee.

BACKGROUND The Riata family of implantable cardioverter-defibrillator (ICD) leads is prone to a specific insulation abrasion characterized by externalization of conductor cables. The objective of this study was to determine the prevalence of externalized conductors and electrical abnormalities in Riata ICD leads by fluoroscopic screening and standard ICD interrogation. METHODS AND RESULTS All...

متن کامل

A Comparative Study of Defibrillator Leads at a Large-Volume Implanting Hospital: Results From the Pacemaker and Implantable Defibrillator Leads Survival Study ("PAIDLESS").

OBJECTIVES The purpose of the study was to examine survival in the implantable defibrillator subset of implanted leads at a large-volume implanting hospital. BACKGROUND Implantable lead survival has been the subject of many multicenter studies over the past decade. Fewer large implanting volume single-hospital studies have examined defibrillator lead failure as it relates to patient survival ...

متن کامل

Externalized Conductor Cables in QuickSite Left Ventricular Pacing Lead and Riata Right Ventricular Lead in a Single Patient: A Common Problem With Silicone Insulation

QuickSite (St Jude Medical, Sylmar, CA, USA) is a silicone and polyurethane-insulated coronary sinus pacing lead. Riata lead (St Jude Medical, Sylmar, CA, USA) is a silicone insulated right ventricular shock lead. Recently, insulation breach of silicone based leads raised a huge concern. Fluoroscopic examination of these two leads in the same patient revealed externalization of these two leads....

متن کامل

Failure-free survival of the Durata defibrillator lead.

AIMS Given design similarities and a common manufacturer, there have been suspicions regarding the Durata™ defibrillator (ICD) lead, in the aftermath of the Riata™ class I recall. We therefore examined the failure-free survival rates of the Durata™ compared with the Riata™ and Sprint Quattro™ ICD leads. METHODS AND RESULTS All patients (n = 2475) implanted with a Durata (n = 828), Riata [n = ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 5 4  شماره 

صفحات  -

تاریخ انتشار 2012