Effect of Saline Injection Mixing on Accuracy of Conductance Lumen Sizing of Peripheral Vessels

نویسندگان

  • Hyo Won Choi
  • Benjamin Jansen
  • David Birrer
  • Ghassan S. Kassab
چکیده

Transient displacement of blood in vessel lumen with saline injection is necessary in the conductance method for measurement of arterial cross-sectional area (CSA). The displacement of blood is dictated by the interactions between arterial flow hemodynamics and saline injection dynamics. The objective of the present study is to understand how the accuracy of conductance measurements is affected by the saline injection. Computational simulations were performed to assess the error in predictions of arterial CSA using conductance measurements over a range of peripheral artery diameters (i.e., 4, 7, and 10 mm) with an introducing catheter (6 Fr.) for various blood flow and saline injection rates. The simulation results were validated using the conductance measurements of the phantoms with known diameters (i.e., 7 and 10 mm). The results demonstrated that a minimum ratio of saline injection rate to blood flow rate of 3 is needed to fully displace the blood and result in accurate measurement of CSA for the peripheral artery sizes considered. Furthermore, the error was shown to be minimized as the detection electrodes are positioned between the distal to the mixing zone induced by saline injection and far downstream (4-8 cm from the injection catheter tip). The present study shows that even for the large peripheral arteries (7-10 mm) where mixing can occur, an appropriate injection rate and detection position can produce accurate measurement of lumen size.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of Peripheral Vascular Sizing with Conductance Guidewire: Theory and Experiment

Although the clinical range of interventions for coronary arteries is about 2 to 5 mm, the range of diameters of peripheral vasculature is significantly larger (about 10 mm for human iliac artery). When the vessel diameter is increased, the spacing between excitation electrodes on a conductance sizing device must also increase to accommodate the greater range of vessel diameters. The increase i...

متن کامل

Conductance catheter measurements of lumen area of stenotic coronary arteries: theory and experiment.

An injection of saline solution is required for the measurement of vessel lumen area using a conductance catheter. The injection of room temperature saline to displace blood in a vessel inevitably involves mass and heat transport and electric field conductance. The objective of the present study is to understand the accuracy of conductance method based on the phenomena associated with the salin...

متن کامل

Impact of surrounding tissue on conductance measurement of coronary and peripheral lumen area.

Parallel conductance (electric current flow through surrounding tissue) is an important determinant of accurate measurements of arterial lumen diameter, using the conductance method. The present study is focused on the role of non-uniform geometrical/electrical configurations of surrounding tissue, which are a primary source of electric current leakage. Computational models were constructed to ...

متن کامل

TRANSLATIONAL PHYSIOLOGY New method to measure coronary velocity and coronary flow reserve

Zhang ZD, Svendsen M, Choy JS, Sinha AK, Huo Y, Yoshida K, Molloi S, Kassab GS. New method to measure coronary velocity and coronary flow reserve. Am J Physiol Heart Circ Physiol 301: H21–H28, 2011. First published May 6, 2011; doi:10.1152/ajpheart.00080.2011.—Coronary flow reserve (CFR) is an important index of coronary microcirculatory function. The objective of this study was to validate the...

متن کامل

Implications of complex anatomical junctions on conductance catheter measurements of coronary arteries.

In vivo, the position of the conductance catheter to measure vessel lumen cross-sectional area may vary depending on where the conductance catheter is deployed in the complex anatomical geometry of arteries, including branches, bifurcations, or curvatures. The objective here is to determine how such geometric variations affect the cross-sectional area (CSA) estimates obtained using the cylindri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013