Simulation of B-scan images from two-dimensional transducer arrays: Part II--Comparisons between linear and two-dimensional phased arrays.
نویسندگان
چکیده
Two-dimensional (2-D) arrays have been proposed as a solution to the degradation in medical ultrasound image quality occurring as a result of asymmetric focusing properties of linear phased array transducers. The 2-D phased transducer array is also capable of electronically steering the symmetrically focused ultrasound beam throughout a three-dimensional volume. In a companion paper the potential of 2-D transducer arrays for medical imaging has been investigated using simulated B-scan images. In this paper, the advantages of 2-D over linear transducer arrays is demonstrated by simulating images of spherical cysts embedded in a large scattering volume. The large elevation beamwidth in the nearfield of a 5 MHz linear phased transducer array results in a severe reduction in the image contrast measured between a 4 mm diameter cyst and the surrounding scattering media. By employing a 2-D array with symmetric focusing, the contrast between the cyst and surrounding scatterers is significantly improved. The use of additional elements in the elevation direction of a linear array is also investigated. In this case the additional elements are included only to focus, but not to steer the ultrasound beam. Using the contrast characteristics of a 4 mm diameter cyst, it is shown that relatively few elevation elements are required to significantly improve the nearfield imaging capability of the linear array.
منابع مشابه
Design, implementation, and comparison of guided wave phased arrays using embedded piezoelectric wafer active sensors for structural health monitoring
Phased array can interrogate large structural areas from a single location using ultrasonic guided waves generated by tuned piezoelectric wafer active sensors that are permanently attached (embedded) to the structure. Various array parameters determine the array beamforming and steering characteristics. This paper aims to bring up several one or two dimension array designs and research on their...
متن کاملAccuracy and precision of measurements obtained from conventional cephalograms and CBCT scan in orthodontics linear diagnostic measurements
Background and Purpose: Due to the important role of imaging in the diagnosis and treatment plan in orthodontics, CBCT (Cone Beam Computed Tomography) images because of their three-dimensional nature, can minimize the disadvantages of two-dimensional images such as magnification, distortion, or superimposition. The purpose of this study was to evaluate the accuracy of conventional cephalograms...
متن کاملCorrelation analysis of three-dimensional strain imaging using ultrasound two-dimensional array transducers.
Two-dimensional (2D) transducer arrays represent a promising solution for implementing real time three-dimensional (3D) ultrasound elastography. 2D arrays enable electronic steering and focusing of ultrasound beams throughout a 3D volume along with improved slice thickness performance when compared to one-dimensional (1D) transducer arrays. Therefore, signal decorrelation caused by tissue motio...
متن کاملPhase-Only Synthesis of Antenna Arrays Using Nonuniform Phased Sampling Method
Nonuniform Phased Sampling method is proposed to phase-only synthesize the power pattern of both linear and planar antenna arrays. This method modifies the conventional sampling method which is used for amplitude-phase synthesis. This method is based on assigning suitable phases to the sampling points of radiation pattern in order to reach desired amplitude of currents. Some examples are given ...
متن کاملThree-dimensional simulation of human teeth and its application in dental education and research
Background: A comprehensive database, comprising geometry and properties of human teeth, is needed for dentistry education and dental research. The aim of this study was to create a three-dimensional model of human teeth to improve the dental E-learning and dental research. Methods: In this study, a cross-section picture of the three-dimensional model of the teeth was used. CT-Scan im...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Ultrasonic imaging
دوره 14 4 شماره
صفحات -
تاریخ انتشار 1992