Axillary loop grafts for hemodialysis access: midterm results from a single-center study.

نویسندگان

  • Elixène Jean-Baptiste
  • Réda Hassen-Khodja
  • Pierre Haudebourg
  • Serge Declemy
  • Michel Batt
  • Pierre Jean Bouillanne
چکیده

PURPOSE This study reports our midterm results with arteriovenous axillary loop grafts (AVALG) and evaluates their role in construction of vascular access for patients on chronic hemodialysis. METHODS The clinical data of 27 patients who underwent construction of an AVALG for hemodialysis access at our institution between July 2002 and December 2006 were analyzed retrospectively. Outcome measures included graft patency, the complication rate, and the frequency and morbidity of secondary procedures after AVALG creation. The Kaplan-Meier method was used to calculate the primary and secondary patency curves. RESULTS AVALG was constructed as the first access procedure in eight patients: five patients with no suitable vein to construct an adequate angioaccess on the upper limbs, and three patients with elbow and forearm arteritis. The 19 other patients had all had two to five failed prior vascular accesses leading to exhaustion of venous access sites on the upper extremities (18 cases), or a steal syndrome (one case). No postoperative death occurred, but four patients died of causes unrelated to the intervention between the second and the tenth postoperative months. The mean follow-up was 15 months (range, 2-48 months). The primary patency rate at 12 months and the secondary patency rate at 18 months were 51% and 80%, respectively. Infection (three cases), thrombosis (seven cases), and stenosis of the outflow vein (two cases) were the main complications, occurring in 10 of the 27 patients (41%). Twelve secondary procedures were performed in these 10 patients with little additional morbidity. Five of the 27 patients developed irreversible AVALG occlusion leading to access loss: two patients with concomitant graft infection and three patients with a history of subclavian vein catheterization. CONCLUSION AVALG may represent a supplementary option for chronic hemodialysis patients with vascular steal or inadequate upper extremity venous access sites.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Midterm Experience of Ipsilateral Axillary-Axillary Arteriovenous Loop Graft as Tertiary Access for Haemodialysis

Objectives. To present a series of ipsilateral axillary artery to axillary vein loop arm grafts as an alternative vascular access procedure for haemodialysis in patients with difficult access. Design. Retrospective case series. Methods. Patients who underwent an axillary loop arteriovenous graft from September 2009 to September 2012 were included. Preoperative venous imaging to exclude central ...

متن کامل

Upper Extremity Axillary Loop Grafts: An Opportunity in Hemodialysis Access

BACKGROUND Dialysis vascular access complications are considered as significant causes of morbidity in chronic hemodialysis patients. OBJECTIVES The aim of the present study was a comparison of axillary loop and straight grafts patency and its complications in hemodialysis access. PATIENTS AND METHODS In this cohort study conducted at Shahid Beheshti Medical University, 77 patients who unde...

متن کامل

Arterioarterial prosthetic loop: a new approach for hemodialysis access.

OBJECTIVES In this report we present a novel procedure that uses an arterioarterial prosthetic loop (AAPL) with the proximal axillary or the femoral artery as a vascular access for hemodialysis in patients who have inadequate vascular conditions for creating an arteriovenous fistula or graft. METHODS Between April 1996 and September 2004, 34 patients received 36 AAPLs as vascular access, eith...

متن کامل

VASCULAR ACCESS FOR HEMODIALYSIS: OUR EXPERIENCE WITH 3337 CASES

Over a seven year period from 1982 to 1989,3337 conduits were created in 3137 patients with end stage renal disease (ESRD) as access for chronic dialysis. These included 2690 side-to-side arteriovenous fistulae (A VF), 168 end-to-side A VFs, 10 autogenous vein grafts, 51 homogenous frozen vein grafts, 109 polytetrafluoroethylene (PTFE) grafts, 209 emergency external arteriovenous shunts, t...

متن کامل

Percutaneous Intervention in Axillary Loop-Configured Arteriovenous Grafts for Chronic Hemodialysis Patients

OBJECTIVE The purpose of this study was to evaluate the fistulographic features of malfunctioning axillary loop-configured arteriovenous grafts and the efficacy of percutaneous interventions in failed axillary loop-configured arteriovenous grafts. MATERIALS AND METHODS Ten patients with axillary loop-configured arteriovenous grafts were referred for evaluation of graft patency or upper arm sw...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of vascular surgery

دوره 47 1  شماره 

صفحات  -

تاریخ انتشار 2008