Dual-mobility cups for revision due to instability are associated with a low rate of re-revisions due to dislocation

نویسندگان

  • Nils P Hailer
  • Rüdiger J Weiss
  • André Stark
  • Johan Kärrholm
چکیده

BACKGROUND AND PURPOSE Revision total hip arthroplasty (THA) due to recurrent dislocations is associated with a high risk of persistent instability. We hypothesized that the use of dual-mobility cups would reduce the risk of re-revision due to dislocation after revision THA. PATIENTS AND METHODS 228 THA cup revisions (in 228 patients) performed due to recurrent dislocations and employing a specific dual-mobility cup (Avantage) were identified in the Swedish Hip Arthroplasty Register. Kaplan-Meier survival analysis was performed with re-revision due to dislocation as the primary endpoint and re-revision for any reason as the secondary endpoint. Cox regression models were fitted in order to calculate the influence of various covariates on the risk of re-revision. RESULTS 58 patients (25%) had been revised at least once prior to the index cup revision. The surgical approach at the index cup revision was lateral in 99 cases (44%) and posterior in 124 cases (56%). Median follow-up was 2 (0-6) years after the index cup revision, and by then 18 patients (8%) had been re-revised for any reason. Of these, 4 patients (2%) had been re-revised due to dislocation. Survival after 2 years with the endpoint revision of any component due to dislocation was 99% (95% CI: 97-100), and it was 93% (CI: 90-97) with the endpoint revision of any component for any reason. Risk factors for subsequent re-revision for any reason were age between 50-59 years at the time of the index cup revision (risk ratio (RR) = 5 when compared with age > 75, CI: 1-23) and previous revision surgery to the relevant joint (RR = 1.7 per previous revision, CI: 1-3). INTERPRETATION The risk of re-revision due to dislocation after insertion of dual-mobility cups during revision THA performed for recurrent dislocations appears to be low in the short term. Since most dislocations occur early after revision THA, we believe that this device adequately addresses the problem of recurrent instability. Younger age and prior hip revision surgery are risk factors for further revision surgery. However, problems such as potentially increased liner wear and subsequent aseptic loosening may be associated with the use of such devices in the long term.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dual Mobility Cups for Preventing Early Hip Arthroplasty Dislocation in Patients at Risk: Experience in a County Hospital

Dislocation remains a major concern after hip arthroplasty. We asked whether dual mobility cups (DMC) would improve early hip stability in patients with high risk of dislocation. We followed 34 patients (21 females, 13 males) treated between 2009 and 2012 with cemented DMC for hip revisions caused recurrent hip prosthetic dislocation or as a primary procedure in patients with high risk of insta...

متن کامل

Comparison of dual-mobility cup and unipolar cup for prevention of dislocation after revision total hip arthroplasty

Background and purpose - Revision total hip arthroplasty (THA) is associated with higher dislocation rates than primary THA. We compared the risk of dislocation within 6 months and all-cause re-revision during the whole study period using either the dual-mobility cup or the unipolar cup. Methods - We used a prospective hospital registry-based cohort including all total and cup-only revision THA...

متن کامل

Effects of hydroxyapatite coating of cups used in hip revision arthroplasty

BACKGROUND AND PURPOSE Coating of acetabular revision implants with hydroxyapatite (HA) has been proposed to improve ingrowth and stability. We investigated whether HA coating of revision cups can reduce the risk of any subsequent re-revision. METHODS We studied uncemented cups either with or without HA coating that were used at a primary acetabular revision and registered in the Swedish Hip ...

متن کامل

The Dislocating Hip Replacement – Revision with a Dual Mobility Cup in 56 Consecutive Patients

INTRODUCTION Recurrent dislocations of hip replacements are a difficult challenge. One treatment option for recurrent dislocations is the use of a dual mobility cup. The aim of this study was to retrospective investigate the effect of dual mobility cups as a treatment for recurrent dislocations in a consecutive series. Materials and. METHODS 56 consecutive patients were revised in the period ...

متن کامل

The risk of revision due to dislocation after total hip arthroplasty depends on surgical approach, femoral head size, sex, and primary diagnosis

BACKGROUND AND PURPOSE The effects of patient-related and technical factors on the risk of revision due to dislocation after primary total hip arthroplasty (THA) are only partly understood. We hypothesized that increasing the femoral head size can reduce this risk, that the lateral surgical approach is associated with a lower risk than the posterior and minimally invasive approaches, and that g...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 83  شماره 

صفحات  -

تاریخ انتشار 2012