Analysis of renal artery morphometery in adults: A study conducted by using Multidetector computed Tomography Angiography

نویسندگان

  • Maria Mohiuddin
  • Arsalan Manzoor
  • Muhammad Ali
  • Nuzhat Hassan
چکیده

OBJECTIVE To determine a reference range of renal artery measurements by using Multidetector Computed Tomography (MDCT) angiography and to find association of renal artery measurements with side of artery, gender and age. METHOD Two hundred and fifty study participants without renal artery disease who werepresented to Radiology Department, Ziauddin Hospital, Karachi, from November, 2016 to April, 2017 were included in this study. Main renal artery measurements were taken on Multidetector computed angiography and variation with side, gender and age were analyzed. Statistical analysis was done on Statistical Package for Social Sciences (SPSS) version 20. Independent sample T test, one way ANOVA and Pearson's correlation analysis were applied. P-value of < 0.05 was considered significant. RESULTS A significance difference (p=0.001) was seen between mean right renal artery (diameter 6.66 ± 0.39 mm; length 44.69 ± 2.48 mm) and left renal artery (diameter 6.79 ± 0.36; length 35.10 ± 2.86 mm). Females found to have smaller mean diameter and length of renal arteries than males. However, a weak negative correlation was seen between mean renal artery diameter and age (right r= -0.158, p=0.0121; left r= -0.017, p= 0.708). CONCLUSION The mean diameter and mean length were found to be significantly different between right and left main renal artery and between males and females. A significant weak negative correlation was observed between renal artery diameter and age.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multiple renal arteries: variations demonstrated by multidetector computed tomography angiography.

OBJECTIVE To present a case of a rare variation of the renal artery and multiple (7) renal arteries by multidetector computed tomography (MDCT) angiography. CLINICAL PRESENTATION AND INTERVENTION A 36-year-old male patient was admitted to our hospital as a potential living donor for renal transplantation. An MDCT angiography was performed using a 16-detector row CT scanner to obtain a detaile...

متن کامل

Isolated spontaneous renal artery dissection: diagnosis and endovascular management.

Spontaneous, isolated focal renal artery dissection is an extremely rare cause of renovascular hypertension. Imaging technology for the renal arteries has evolved recently with the development of multidetector computed tomography angiography (CTA), and intravascular ultrasound. We describe a 52-year-old man with spontaneous renal artery dissection complicated by renovascular hypertension, succe...

متن کامل

Role of Multidetector Computed Tomography for Evaluation of Living Kidney Donors

BACKGROUND Kidney transplantation from living donors has been increased recently. Preoperative evaluation of living donor is important to select the appropriate kidney for transplantation and to decrease donor surgical complications. OBJECTIVES The aim of this study was to compare the accuracy of the use of multidetector computed tomography (MDCT) to evaluate vascular anatomy in living kidney...

متن کامل

CT angiography of renal arteries: anatomy, variants and its importance in the living donor

Background: Kidneys are retroperitoneal organs normally supplied by the paired renal arteries.. Living donor renal transplantation, as opposed to cadaveric donation, is the best opinion for the recipient and graft survival. The need for kidney transplantation has undergone exponential growth over the past 40 years, and cadaveric donations are inadequate to meet this ever-increasing demand. Thes...

متن کامل

Comparison of Image Quality of Low Voltage 64-slice Multidetector CT Angiography with the Standard Condition in Patients Suspected of Pulmonary Embolism

Introduction: Reduction of peak kilovoltage (kV) setting has been a useful approach to d creating radiation dose; however, it may have varied effects on noise and the accuracy of diagnosis. Thus, we compared image quality between low (80 kV) and standard kilovoltage (100 kV) protocols. Material and Methods: This triple blind non-randomized parallel quasi-experimental study was conducted on 140 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 33  شماره 

صفحات  -

تاریخ انتشار 2017