Peptide Orientation Affects Selectivity in Ion-Exchange Chromatography

نویسندگان

  • Andrew J. Alpert
  • Konstantinos Petritis
  • Lars Kangas
  • Richard D. Smith
  • Karl Mechtler
  • Goran Mitulović
  • Shabaz Mohammed
  • Albert J. R. Heck
چکیده

Here we demonstrate that separation of proteolytic peptides, having the same net charge and one basic residue, is affected by their specific orientation toward the stationary phase in ion-exchange chromatography. In electrostatic repulsion-hydrophilic interaction chromatography (ERLIC) with an anion-exchange material, the C-terminus of the peptides is, on average, oriented toward the stationary phase. In cation exchange, the average peptide orientation is the opposite. Data with synthetic peptides, serving as orientation probes, indicate that in tryptic/Lys-C peptides the C-terminal carboxyl group appears to be in a zwitterionic bond with the side chain of the C-terminal Lys/Arg residue. In effect, the side chain is then less basic than the N-terminus, accounting for the specific orientation of tryptic and Lys-C peptides. Analyses of larger sets of peptides, generated from lysates by either Lys-N, Lys-C, or trypsin, reveal that specific peptide orientation affects the ability of charged side chains, such as phosphate residues, to influence retention. Phosphorylated residues that are remote in the sequence from the binding site affect retention less than those that are closer. When a peptide contains multiple charged sites, then orientation is observed to be less rigid and retention tends to be governed by the peptide's net charge rather than its sequence. These general observations could be of value in confirming a peptide's identification and, in particular, phosphosite assignments in proteomics analyses. More generally, orientation accounts for the ability of chromatography to separate peptides of the same composition but different sequence.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Factors affecting selectivity in ion chromatography.

Methods for separation of ions by ion-exchange, ion-pair, and zwitterion ion chromatography share at least one common thread--the induced formation of a cation-anion pair in the stationary phase. Selectivity can be defined as the relative ability of sample ions to form such a pair. Examples are given in anion-exchange chromatography to show the effect of variations in the geometry, bulkiness an...

متن کامل

Immunoglobulin A Preparation from Human Pooled Plasma Using Plasma Fractionation and Ion Exchange Chromatography

Background: In this study we have prepared the IgA solution from normal human plasma using plasma fractionation and ion exchange chromatography. Materials and Methods: Using fractionation of plasma with cold ethanol (starting with 8% ethanol), fraction III was prepared as a suitable source for IgA preparation. Then it was treated with caprylic acid for separation of impurities. For enrichm...

متن کامل

Isolation and purification of albumin from human plasma by direct and combined approach of ion-exchange chromatography and comparison of the final products quality obtained by both methods

Background: Due to multiple roles of albumin in the body, injection of its medicinal product as one of the therapeutic or management strategies under conditions such as severe bleeding, burns, liver failure, and neonatal hemolytic diseases is on the physicians' agenda. Considering that albumin is the most abundant plasma protein, designing an appropriate method to purify it is highly important....

متن کامل

Partial purification and characterization of two Peptide hydrolases from pea seeds.

Two peptide hydrolases have been found in pea seeds (Pisum sativum var. Greenfeast) and extensively purified by ion exchange chromatography using benzoyl-dl-arginine-p-nitroanilide as substrate. The enzymes which both have molecular weights of 65,000 can be separated by anion exchange chromatography but are otherwise virtually identical in the properties tested. They did not hydrolyze several c...

متن کامل

Methods Development Using Ion-Pair Chromatography with Suppressed Conductivity Detection

INTRODUCTION Mobile-phase ion chromatography (MPIC) is a technique that combines ion-pair chromatography with suppressed conductivity detection. Ion-pair chromatography is commonly used in combination with UV detection, in which case it is referred to as reversedphase ion-pair chromatography (RPIPC). MPIC has the advantage of using conductivity detection, which serves as a universal detection m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 82  شماره 

صفحات  -

تاریخ انتشار 2010