Comparison of volar locking plate and external fixation with K wire augmentation in unstable distal radius fractures

نویسنده

  • Rabindra L Pradhan
چکیده

Distal radius fractures are one of the most common injuries and this incidence is likely to increase as the aging population increases. The type of operation and implant is a matter of discussion and randomized trials and meta analyses have failed to recommend the preferred implant. Internal fixation with volar locking plate and external fixation with supplementation with K wire have been successfully employed in these fractures. Forty eight patients unstable distal radius fractures treated from 2008 to 2014 with either a volar locking plate or an external fixation with K wire supplementation were analyzed. Radiographic measurements like dorsal angle in degrees, radial inclination in degrees, ulnar variance in millimeters and radial length in millimeters were taken. Functional evaluation was assessed with the clinical rating as devised by Cooney (modified from Green and O’Brien). These patients were treated with volar locking plate (n26) and external fixation with K wire (n-22). Patients were treated with a three or four holes 3.5mm volar locking plate and wrist spanning external fixator with two K wire supplementation. Sixteen A3, fourteen C1, eleven C2, and seven C3 fractures were treated. By six weeks, the mean functional outcome score in the volar plate group was significantly better than that in the external fixation group (p =0.037). At three months, the mean score in the volar plate group was significantly better than that in the external fixation group (p = 0.028). However, by six months, the score in the volar plate group was not significantly different from that in the external fixation group (p = 0.26). At one year, the mean score in the volar plate was not significantly different from the mean score in the external fixation group (p = 0.056). At one year, the degree of radial inclination and the radial length in the patients with a volar locking plate were significantly greater than those in both the patients treated with external fixation (p = 0.007 and p = 0.002, respectively). Although volar locking plate has certain advantages over the external fixation in the earlier post operative period, this decreases as time passes. Both fixation techniques seem to apply sufficient stabilization to restore and retain anatomy after fracture of distal part of the radius and should be individually chosen accordingly.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Volar locking plate fixation versus Kirschner wire fixation in distal radius fractures: a meta-analysis

Objective: The superiority of volar locking plate fixation and K-wire fixation on treatment of distal radius fractures was controversial. Thus, we performed a meta-analysis to compare the efficacy of volar locking plate and K-wires for distal radius fracture. Methods: We searched Embase, Medline and PubMed for randomized controlled trials which compare the effects of volar locking plate and K-w...

متن کامل

Complications and Plate Removal Surgeries after Performing Volar Plating of Unstable Distal Radius Fractures

Complications have often been reported in the literature after distal radius fractures treated conservatively or operatively [1-3]. Previously, the main indication for volar plating was a volar Barton or Smith fracture, but now volar locking plates are the most commonly used treatment for unstable distal radius fractures and during the last decade this method has become increasingly popular [4]...

متن کامل

Evaluation of a novel, nonspanning external fixator for treatment of unstable extra-articular fractures of the distal radius: biomechanical comparison with a volar locking plate.

PURPOSE To compare the stability of a novel, nonspanning external fixator with a standard volar locked plate for treatment of unstable distal radius fractures. METHODS A simulated, unstable, extra- articular distal radius fracture was created in six matched pairs of fresh frozen human distal radii. One of each pair was treated with a nonspanning external fixator [Mirza Cross Pin Fixator (CPX)...

متن کامل

Treatment of unstable distal radius fractures with the volar locking plate

BACKGROUND Open reduction and internal fixation using an interlocking plate system has gained popularity for the treatment of dorsally displaced distal radius fractures. PURPOSE To evaluate the functional and radiological results of treating unstable distal radius fractures with the volar locking plate. PATIENTS AND METHODS A retrospective review was conducted of patients from one instituti...

متن کامل

Efficacy of volar and dorsal plate fixation for unstable dorsal distal radius fractures.

OBJECTIVE To compare the efficacy of volar and dorsal plate fixation for unstable dorsal distal radius fractures. METHODS Forty-seven cases were selected from patients undergoing surgical reduction and internal fixation treatment in our hospital from August 2006 to October 2010, with 21 males and 26 females, aged 39-73 years old. Patients were divided into two groups: volar plate fixation gro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016