Distal femoral replacement by custom-made prostheses. Clinical follow-up and survivorship analysis.
نویسندگان
چکیده
We report the long-term clinical follow-up and survivorship analysis of 40 distal femoral replacements performed between 1964 and 1980 for traumatic, locally aggressive and malignant conditions. Custom-made prostheses with fully-constrained knee joints were used to replace a mean of 42% of the length of the femur. Survivorship analysis showed a cumulative success rate of 80% at eight years, with no subsequent deterioration at 18 years. Clinical assessment revealed 78% excellent or good results. Failure was due to infection in three cases, and in two to fracture of a now-outmoded femoral stem.
منابع مشابه
Prosthetic replacement of the distal femur for primary bone tumours.
Over a 16-year period, 135 custom-made distal femoral prostheses, based on a fully constrained Stanmore-type knee replacement, were used in the treatment of primary malignant or aggressive benign tumours. Survivorship analysis showed a cumulative success rate of 72% at five years and 64% at seven years. Intact prostheses in 91% of the surviving patients gave good or excellent functional results...
متن کاملAseptic loosening in cemented custom-made prosthetic replacements for bone tumours of the lower limb.
We have made a retrospective study of 1001 custom-made prostheses used as replacements after surgery for bone tumours. There were 493 distal femoral, 263 proximal femoral and 245 proximal tibial prostheses. Aseptic loosening was shown to be the principal mode of failure of the implants, and 71 patients had revision for aseptic loosening of a cemented intramedullary stem. The probability of a pa...
متن کاملCemented Distal Femoral Endoprostheses for Musculoskeletal Tumor: Improved Survival of Modular versus Custom Implants
BACKGROUND Advocates of newer implant designs cite high rates of aseptic loosening and failure as reasons to abandon traditional cemented endoprosthetic reconstruction of the distal femur. QUESTIONS/PURPOSES We asked whether newer, modular distal femoral components had improved survivorship compared with older, custom-casted designs. PATIENTS AND METHODS We retrospectively reviewed 254 pati...
متن کاملSingle Cut Distal Femoral Varus Osteotomy (SCFO): A Preliminary Study
Background: Genu valgum usually originates from a deformity of distal femur that is often corrected by distal femoralvarus osteotomy. The osteotomy includes both components of angulationcorrection and translation because the siteof osteotomy is not commonly at the apex of deformity. Improvement of patellar tracking not only depends on valguscorrection, but also it may be partially due to centra...
متن کاملAsian-Specific total knee system: 5-14 year follow-up study
BACKGROUND Knee size and body size differ in Asians compared with Caucasians. Nevertheless, many total knee arthroplasty (TKA) prostheses used worldwide are made for Western Caucasian subjects. As a result, an Asian's knee might not fit these prostheses. We studied the Flexible Nichidai Knee (FNK) system, a new model of TKA for Asian patients. The purpose of this report is to investigate the ou...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 69 2 شماره
صفحات -
تاریخ انتشار 1987