Multicenter Study of Creatinine- and/or Cystatin C-Based Equations for Estimation of Glomerular Filtration Rates in Chinese Patients with Chronic Kidney Disease

نویسندگان

  • Jia-fu Feng
  • Ling Qiu
  • Lin Zhang
  • Xue-mei Li
  • Yu-wei Yang
  • Ping Zeng
  • Xiu-zhi Guo
  • Yan Qin
  • Hong-chun Liu
  • Xing-min Han
  • Yan-peng Li
  • Wei Xu
  • Shu-yan Sun
  • Li-qiang Wang
  • Hui Quan
  • Li-jun Xia
  • Hong-zhang Hu
  • Fang-cai Zhong
  • Rong Duan
چکیده

OBJECTIVE To establish equations for the estimation of glomerular filtration rates (eGFRs) based on serum creatinine (SCr) and/or serum cystatin C (SCysC) in Chinese patients with chronic kidney disease (CKD), and to compare the new equations with both the reference GFR (rGFR) and the literature equations to evaluate their applicability. METHODS The 788 Chinese CKD patients were randomly divided into two groups, the training group and the testing group, to establish new eGFR-formulas based on serum CysC and to validate the established formulas, respectively. (99m)Tc-DTPA clearance (as the rGFR), serum Cr, and serum CysC were determined for all patients, and GFR was calculated using the Cockcroft-Gault equation (eGFR1), the MDRD formula (eGFR2), the CKD-EPI formulas (eGFR3, eGFR4), and the Chinese eGFR Investigation Collaboration formulas (eGFR5, eGFR6). The accuracy of each eGFR was compared with the rGFR. RESULTS The training and testing groups' mean GFRs were 50.84±31.36 mL/min/1.73 m(2) and 54.16±29.45 mL/min/1.73 m(2), respectively. The two newly developed eGFR formulas were fitted using iterative computation: [Formula: see text] and [Formula: see text]. Significant correlation was observed between each eGFR and the rGFR. However, proportional errors and constant errors were observed between rGFR and eGFR1, eGFR2, eGFR4, eGFR5 or eGFR6, and constant errors were observed between eGFR3 and rGFR, as revealed by the Passing & Bablok plot analysis. The Bland-Altman analysis illustrated that the 95% limits of agreement of all equations exceeded the previously accepted limits of <60 mL/min •1.73 m(2), except the equations of eGFR7 and eGFR8. CONCLUSION The newly developed formulas, eGFR7 and eGFR8, provide precise and accurate GFR estimation using serum CysC detection alone or in combination with serum Cr detection. Differences in detection methods should be carefully considered when choosing literature eGFR equations to avoid misdiagnosis and mistreatment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of creatinine- and/or cystatin C-based glomerular filtration rate estimation equations in elderly Chinese

BACKGROUND No conventional creatinine- or cystatin C-based glomerular filtration rate (GFR) estimation equation performed consistently outstandingly in elderly Chinese in our previous studies. This research aimed to further evaluate the performance of some recently proposed estimation equations based on creatinine and cystatin C, alone or combined, in this specific population. MATERIALS AND M...

متن کامل

Comparative Assessment of Neutrophil Gelatinase-Associated Lipocalin (NGAL) and Cystatin C as Early Biomarkers for Early Detection of Renal Failure in Patients with Hypertension

Background: Hypertension is one the most common causes of chronic kidney disease (CKD). One of the major concerns in hypertensive patients is early detection of renal disorders. In the past, serum creatinine (Scr) concentration was used as a marker of kidney function, but it proffers a late reflection of reduced glomerular filtration rate. Cystatin C and neutrophil gelatinase-associated lipocal...

متن کامل

Comparison of Serum Cystatin C and Creati-nine Levels to Evaluate Early Renal Function after Kidney Transplantation

Background: Accurate and rapid assessment of allograft function is essential in renal transplant recipients in order to detect allograft rejection and to monitor drug nephrotoxicity. We aimed to evaluate the usefulness of cystatin C as a marker of kidney allograft function in the early post-transplant period and to compare this value with that of conventional serum creatinine concentration. Met...

متن کامل

Simple Cystatin C Formula for Estimation of Glomerular Filtration Rate in Overweight Patients with Diabetes Mellitus Type 2 and Chronic Kidney Disease

In clinical practice the glomerular filtration rate (GFR) is estimated from serum creatinine-based equations like the Cockcroft-Gault formula (C&G) and Modification of Diet in Renal Disease formula (MDRD). Recently, serum cystatin C-based equations, the newer creatinine formula (The Chronic Kidney Disease Epidemiology Collaboration formula (CKD-EPI)), and equation that use both serum creatinine...

متن کامل

Estimating glomerular filtration rates by use of both cystatin C and standardized serum creatinine avoids ethnicity coefficients in Asian patients with chronic kidney disease.

BACKGROUND The Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equation is most accurate for estimating glomerular filtration rate (GFR) but requires an adjustment for African-American patients. Estimation equations are also improved with the use of serum cystatin C combined with standardized creatinine. Combination equations have been derived by the CKD-EPI and Chinese investigator...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013