High incidence of rainbow glare after femtosecond laser assisted-LASIK using the upgraded FS200 femtosecond laser
نویسندگان
چکیده
BACKGROUND To compare the incidence of rainbow glare (RG) after femtosecond laser assisted-LASIK (FS-LASIK) using the upgraded FS200 femtosecond laser with different flap cut parameter settings. METHODS A consecutive series of 129 patients (255 eyes) who underwent FS-LASIK for correcting myopia and/or astigmatism using upgraded WaveLight FS200 femtosecond laser with the original settings was included in group A. Another consecutive series of 129 patients (255 eyes) who underwent FS-LASIK using upgraded WaveLight FS200 femtosecond laser with flap cut parameter settings changed (decreased pulse energy, spot and line separation) was included in group B. The incidence and fading time of RG, confocal microscopic image and postoperative clinical results were compared between the two groups. RESULTS There were no differences between the two groups in age, baseline refraction, excimer laser ablation depth, postoperative uncorrected visual acuity and refraction. The incidence rate of RG in group A (35/255, 13.73%) was significantly higher than that in group B (4/255, 1.57%) (P < 0.05). The median fading time was 3 months in group A and 1 month in group B (P > 0.05).The confocal microscopic images showed wider laser spot spacing in group A than group B. The incidence of RG was significantly correlated with age and grouping (P < 0.05). CONCLUSIONS The upgraded FS200 femtosecond laser with original flap cut parameter settings could increase the incidence of RG. The narrower grating size and lower pulse energy could ameliorate this side effect.
منابع مشابه
Simultaneous Correction of Unilateral Rainbow Glare and Residual Astigmatism by Undersurface Flap Photoablation After Femtosecond Laser-Assisted LASIK.
PURPOSE To report and document a case of successful rainbow glare correction using undersurface ablation of the LASIK flap. METHODS A 33-year-old woman was treated bilaterally for myopia using femtosecond laser-assisted LASIK with the FS200 femtosecond laser (Alcon Laboratories, Inc., Fort Worth, TX). Postoperatively, she complained of rainbow glare in her right eye, and presented some residu...
متن کاملUnilateral rainbow glare after uncomplicated femto-LASIK using the FS-200 femtosecond laser.
PURPOSE To report a case of rainbow glare following femtosecond laser-assisted LASIK (femto-LASIK) with the Wavelight FS-200 femtosecond laser (Alcon Laboratories, Inc., Fort Worth, TX). METHODS A patient was treated bilaterally for myopia with femto-LASIK using the FS-200 femtosecond laser. Postoperatively, he complained of rainbow glare in his right eye. RESULTS Three months postoperative...
متن کاملDigital analysis of flap parameter accuracy and objective assessment of opaque bubble layer in femtosecond laser-assisted LASIK: a novel technique
BACKGROUND The purpose of this study was to determine flap parameter accuracy, extent of the opaque bubble layer, and incidence of skip lines in femtosecond laser-assisted stromal in situ keratomileusis (LASIK) using the WaveLight(®) FS200 laser and optoelectronic clinical measurements. METHODS Images from 101 flaps were automatically recorded during consecutive routine LASIK procedures perfo...
متن کاملPredictability of Corneal Flap Thickness in LASIK Using the WaveLight FS200 Femtosecond Laser
250 of 250 words) Purpose: To compare the intended versus resultant thickness of laser in situ keratomileusis (LASIK) flaps created with a new femtosecond laser (WaveLight FS200 Femtosecond Laser, WaveLight GmbH, Alcon Laboratories) and to report refractive outcomes at 3 months posttreatment. Setting: Wellington Eye Clinic, Dublin, Ireland Design: Retrospective consecutive case series Methods: ...
متن کاملEssential opaque bubble layer elimination with novel LASIK flap settings in the FS200 Femtosecond Laser
BACKGROUND The purpose of this study is to evaluate the extent and incidence of opaque bubble layer (OBL) using laser-assisted in situ keratomileusis (LASIK) flaps created with the Alcon/WaveLight® FS200 femtosecond laser as a result of a recent change in flap programming parameters aiming to reduce further the incidence and extent of OBL. METHODS Intraoperative digital images of flaps from 3...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 18 شماره
صفحات -
تاریخ انتشار 2018