The effects of cardiopulmonary bypass with hollow fiber membrane oxygenator on blood clotting measured by thromboelastography.
نویسندگان
چکیده
In cardiac surgical patients we investigated the effects of cardiopulmonary bypass (CPB) with a hollow fiber membrane oxygenator on blood clotting measured by thromboelastography (TEG). We found only a minimal change in the strength of blood clot described either by the TEG parameter MA (maximum amplitude) or by the shear modulus G calculated from MA. After CPB there was also a significant tendency towards hypercoagulation as defined by shortened parameters R, K and increased a-angle. After comparison with published data obtained in cardiac surgical patients using a bubble oxygenator we conclude that currently used extracorporeal technology exerts a less negative influence on blood clotting than had been conceived previously.
منابع مشابه
Impact of hollow-fiber membrane surface area on oxygenator performance: Dideco D903 Avant versus a prototype with larger surface area.
This study compares the gas transfer capacity, the blood trauma, and the blood path resistance of the hollow-fiber membrane oxygenator Dideco D 903 with a surface area of 1.7 m2 (oxygenator 1.7) versus a prototype built on the same principles but with a surface area of 2 m2 (oxygenator 2). Six calves (mean body weight: 68.2 +/- 3.2 kg) were connected to cardiopulmonary bypass (CPB) by jugular v...
متن کاملGas transfer performance of a hollow fiber silicone membrane oxygenator: ex vivo study.
Based on the results of in vitro studies of many experimental models, a silicone hollow fiber membrane oxygenator for pediatric cardiopulmonary bypass (CPB) and extracorporeal membrane oxygenation (ECMO) was developed using an ultrathin silicone hollow fiber with a 300 microm outer diameter and a wall thickness of 50 microm. In this study, we evaluated the gas transfer performance of this oxyge...
متن کاملEffect of Normobaric versus Hypobaric Oxygenation on Gaseous Microemboli Removal in a Diffusion Membrane Oxygenator: An In Vitro Comparison.
Gaseous microemboli (GME) are an abnormal physiological occurrence during cardiopulmonary bypass and extracorporeal membrane oxygenation (ECMO). Several studies have correlated negative sequelae with exposure to increased amounts of GME. Hypobaric oxygenation is effective at eliminating GME in hollow-fiber microporous membrane oxygenators. However, hollow-fiber diffusion membrane oxygenators, w...
متن کاملPreclinical evaluation of a new hollow fiber silicone membrane oxygenator for pediatric cardiopulmonary bypass: ex-vivo study.
Based on the results of many experimental models, a hollow fiber silicone membrane oxygenator applicable for long-term extracorporeal membrane oxygenation (ECMO) was developed. For further high performance and antithrombogenicity, this preclinical model was modified, and a new improved oxygenator was successfully developed. In addition to ECMO application, the superior biocompatibility of silic...
متن کاملExperimental evaluation of the Medtronic Maxima Forté hollow fiber membrane oxygenator.
A new hollow fiber membrane oxygenator, the Medtronic Maxima Forté, was tested for gas transfer, blood path resistance and blood handling characteristics in a standardized setting with surviving animals. Three calves (mean body weight: 71 +/- 9.6 kg) were placed on cardiopulmonary bypass at a mean flow rate of 50 ml/kg/min for six hours. The circuit included the Maxima Forté oxygenator. The ani...