Stator Current Harmonic Assessment of Induction Motor for Fault Diagnosis
نویسندگان
چکیده
This paper presents an assessment of motor current signature analysis for fault diagnosis of an induction motor. Single phasing fault has been considered and stator current harmonics are analyzed by assessing peaks and symmetry in harmonic spectrums both at normal condition and at fault condition. ‘db4’ is used for current signature analysis wavelet decomposition. A comparative observation is made based on the result obtained by computer simulation. Some distinct and significant changes are found at fault condition which may be very useful for diagnosis of such faults.
منابع مشابه
Stator Turn-to-Turn Fault Detection of Induction Motor by Non-Invasive Method Using Generalized Regression Neural Network
Condition monitoring and protection methods based on the analysis of the machine's current are widely used according to non-invasive characteristics of current transformers. It should be noted that, these sensors are installed by default in the machine control center. On the other hand, condition monitoring based on mathematical methods has been proposed in literature. However, they are model b...
متن کاملStator Current Assessment of an induction Motor at Crawling in Clarke Plane
In this paper stator current during crawling of induction motor has been assessed. Three phase current signals have been transformed into Clarke plane. Specific reference signals having sinusoidal nature and different frequencies have been defined and then areas formed by the real system data with the reference signal have been determined, wherefrom individual contributions of fundamental wavef...
متن کاملOptimal Rotor Fault Detection in Induction Motor Using Particle-Swarm Optimization Optimized Neural Network
This study examined and presents an effective method for detection of failure of conductor bars in the winding of rotor of induction motor in low load conditions using neural networks of radial-base functions. The proposed method used Hilbert method to obtain the stator current signal push. The frequency and signal amplitude of the push stator were used as the input of the neural network and th...
متن کاملDetection of Stator Short Circuit Faults in Three-Phase Induction Motors Using Motor Current Zero Crossing Instants
Stator faults typically have a significant share amongst the common type of faults in industrial three-phase induction (asynchronous) motors. This paper presents a motor current signature analysis (MCSA)-based diagnostics of the stator winding short circuit fault. This type of fault happens due to the destruction of the turn insulation, and can be very detrimental causing motor shutdown. Instea...
متن کاملDesign of an Active Approach for Detection, Estimation and Short-Circuit Stator Fault Tolerant Control in Induction Motors
Three phase induction motors have many applications in industries. Consequently, detecting and estimating the fault and compensate it in a way that the faulty induction motor satisfies the predefined goals are important issues. One of the most common faults in induction motors is the short circuit of the stator winding. In this paper, an active fault-tolerant control system is designed and pres...