Observer performance based on marginal bone tissue visibility in Scanora panoramic radiography and posterior bitewing radiography.

نویسندگان

  • Deimante Ivanauskaite
  • Christina Lindh
  • Madeleine Rohlin
چکیده

OBJECTIVES To evaluate image quality for marginal bone tissue assessment on panoramic radiographs taken with the Scanora dental programme and on posterior bitewing radiographs. METHODS Panoramic and bitewing radiographs were taken of 96 patients. Six observers rated marginal bone level visibility as excellent, acceptable, or unacceptable. Five observers assessed image quality for detection of vertical bone defects and furcation involvements as acceptable or unacceptable. Observer agreement was calculated as overall agreement and kappa values. RESULTS Image quality of 36% of the panoramic and 6% of the bitewing sites was rated unacceptable for marginal bone loss assessment in the maxillae while 8% of the panoramic and bitewing sites in the mandible were unacceptable. For detecting vertical bone defects, image quality was unacceptable at one-third of the maxillary sites and 5% of the mandibular sites on the panoramic radiographs. Detection of furcation involvement was acceptable at most sites on both types of radiographs. Kappa values for intra- and inter-observer agreement were higher for panoramic than for bitewing radiographs. The kappa value for marginal bone loss assessment by several observers was moderate (0.45) for panorama and fair (0.28) for bitewing radiography. Corresponding kappa values for detection of vertical bone defects were substantial (0.62) and fair (0.25). CONCLUSION Image quality as evaluated by visual grading analysis is adequate for marginal bone tissue assessment in mandibular molar and premolar regions and unacceptable in maxillary molar and premolar regions on panoramic radiographs taken with the Scanora technique compared to bitewing radiography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison between Scanora panoramic radiography and bitewing radiography in the assessment of marginal bone tissue.

OBJECTIVES To compare panoramic radiographs made with the Scanora dental program and bitewing radiographs in the assessment of marginal bone tissue. MATERIALS AND METHODS Panoramic and posterior bitewing radiographs were made for 96 consecutive patients. Six observers assessed marginal bone level, and five observers identified the presence or absence of vertical bone defects and furcation inv...

متن کامل

Comparison of Measurements of Alveolar Bone Levels by Clinical, Bitewing and Panoramic Radiography

Gingival and periodontal diseases in their various forms have affected human since the dawn of history. The earliest historical records dealing with medical topics revealed an awareness of periodontal diseases and need for treatment.1 The diagnosis of periodontal diseases which involve the soft and hard tissue destruction should be made systematically and should include both clinical and radiog...

متن کامل

Proximal caries detection accuracy using intraoral bitewing radiography, extraoral bitewing radiography and panoramic radiography.

OBJECTIVE To compare proximal caries detection using intraoral bitewing, extraoral bitewing and panoramic radiography. METHODS 80 extracted human premolar and molar teeth with and without proximal caries were used. Intraoral radiographs were taken with Kodak Insight film (Eastman Kodak Co., Rochester, NY) using the bitewing technique. Extraoral bitewing and panoramic images were obtained usin...

متن کامل

ارزیابی همبستگی فاصله کرست استخوان آلوئول تا CEJ در رادیوگرافی‌های پری‎ایپکال، پانورامیک و بایت‌وینگ با میزان واقعی آن

Statement of Problem: In spite of the limitations of Radiography, diagnosing of periodontal diseases without having accurate radiographs is inadequate because it provides a visible image of the supporting bone to the clinician and works as a fixed measure of the supporting bone during the study.Purpose: The aim of this study is to compare the precision of preiapical, bitewings and panoramic rad...

متن کامل

Agreement of Bitewing and Digital Panoramic Radiographies in the Detection of Proximal Caries

Background & Aims: Conventional radiography is used for the diagnosis of problems such as dental caries and failure in root canal therapy. The diagnosis accuracy of conventional radiography is acceptable in the evaluation of anatomical and pathological structures. However, it seems that by using digital radiography we can obtain more information in this field. The aim of this study is to compar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stomatologija

دوره 10 1  شماره 

صفحات  -

تاریخ انتشار 2008