Effect of platform switching on the peri-implant bone: A finite element study
نویسندگان
چکیده
BACKGROUND There exists a relation between the presence and location of the micro-gap and the loss of peri implant bone. Several authors have shown that the treatments based on the use of platform switching result in less peri-implant bone loss and an increased tissue stability. The purpose of this study was to analyse the effect of the platform switching on the distribution of stresses on the peri-implant bone using the finite element method. MATERIAL AND METHODS A realistic 3D full-mandible finite element model representing cortical bone and trabecular bone was used to study the distribution of the stress on the bone induced by an implant of diameter 4.1 mm. Two abutments were modelled. The first one, of diameter 4.1 mm, was used in the reference model to represent a conventional implant. The second one, of diameter 3.2 mm, was used to represent the implant with platform switching. Both models were subjected to axial and oblique masticatory loads. RESULTS The analyses showed that, although no relevant differences can be found for the trabecular bone, the use of platform switching reduces the maximum stress level in the cortical bone by almost 36% with axial loads and by 40% with oblique loads. CONCLUSIONS The full 3D Finite Element model, that can be used to investigate the influence of other parameters (implant diameter, connexion type, …) on the biomechanical behaviour of the implant, showed that this stress reduction can be a biomechanical reasons to explain why the platform switching seems to reduce or eliminate crestal bone resorption after the prosthetic restoration. KEY WORDS Dental implant, platform switching, finite element method.
منابع مشابه
تعیین توزیع تنش استخوان اطراف ایمپلنتهای فک پایین در طرحهای مختلف پروتز به هنگام Mandibular- Flexure
Statement of Problem: In the treatment of edentulous patients with implant supported fixed partial dentures several factors such as implant numbers, implant position, superstructure pattern and cantilever length must be considered. Mandibular flexture in function exerts forces in peri-implant bone, however this phenomenon has received little attention. Purpose: The goal of this finite element a...
متن کاملBiomechanical Effects of Platform Switching in Two Different Implant Systems: A Three-Dimensional Finite Element Analysis
OBJECTIVES The purpose of this study was to determine the influence of platform switching on stress distribution of two different implant systems using three-dimensional (3D) finite element models. MATERIALS AND METHODS Six 3D finite element models were created to replicate two different implant systems with peri-implant bone tissue, in which six different implant-abutment configurations were...
متن کاملImmediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis
Immediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis Dr. A. Fazel * - Dr. SH. A. Alai ** - Dr. M. Rismanchian *** *Associate Professor of Prosthodontics Dept., Faculty of Dentistry and Dental Research Center, Tehran University / Medical Sciences. **Assistant Professor of Prosthodontics Dept., Faculty of...
متن کاملThree-dimensional finite element analysis of platform switched implant
PURPOSE The purpose of this study was to analyze the influence of the platform switching concept on an implant system and peri-implant bone using three-dimensional finite element analysis. MATERIALS AND METHODS Two three-dimensional finite element models for wide platform and platform switching were created. In the wide platform model, a wide platform abutment was connected to a wide platform...
متن کاملتعیین توزیع تنش و کرنش استخوان اطراف ایمپلنت در طرح All-on-4 به روش آنالیز اجزای محدود
Background and Aims: The All-on-4 design with its significant advantages is an appropriate model in reconstruction of edentulous mandible. Evaluation of stress and strain distribution in this model is necessary for better judgment. The purpose of this FEA study was to measure stress and strain distribution on peri-implant bone in All-on-4 design in edentulous mandible. Materials and Methods: Th...
متن کاملذخیره در منابع من