Imaging and quantitation of cannabinoid CB1 receptors in human and monkey brains using (18)F-labeled inverse agonist radioligands.

نویسندگان

  • Garth E Terry
  • Jussi Hirvonen
  • Jeih-San Liow
  • Sami S Zoghbi
  • Robert Gladding
  • Johannes T Tauscher
  • John M Schaus
  • Lee Phebus
  • Christian C Felder
  • Cheryl L Morse
  • Sean R Donohue
  • Victor W Pike
  • Christer Halldin
  • Robert B Innis
چکیده

UNLABELLED We recently demonstrated that (11)C-MePPEP, a PET ligand for CB(1) receptors, has such high uptake in the human brain that it can be imaged for 210 min and that receptor density can be quantified as distribution volume (V(T)) using the gold standard of compartmental modeling. However, (11)C-MePPEP had relatively poor retest and intersubject variabilities, which were likely caused by errors in the measurements of radioligand in plasma at low concentrations by 120 min. We sought to find an analog of (11)C-MePPEP that would provide more accurate plasma measurements. We evaluated several promising analogs in the monkey brain and chose the (18)F-di-deutero fluoromethoxy analog ((18)F-FMPEP-d(2)) to evaluate further in the human brain. METHODS (11)C-FMePPEP, (18)F-FEPEP, (18)F-FMPEP, and (18)F-FMPEP-d(2) were studied in 5 monkeys with 10 PET scans. We calculated V(T) using compartmental modeling with serial measurements of unchanged parent radioligand in arterial plasma and radioactivity in the brain. Nonspecific binding was determined by administering a receptor-saturating dose of rimonabant, an inverse agonist at the CB(1) receptor. Nine healthy human subjects participated in 17 PET scans using (18)F-FMPEP-d(2), with 8 subjects having 2 PET scans to assess retest variability. To identify sources of error, we compared intersubject and retest variability of brain uptake, arterial plasma measurements, and V(T). RESULTS (18)F-FMPEP-d(2) had high uptake in the monkey brain, with greater than 80% specific binding, and yielded less radioactivity uptake in bone than did (18)F-FMPEP. High brain uptake with (18)F-FMPEP-d(2) was also observed in humans, in whom V(T) was well identified within approximately 60 min. Retest variability of plasma measurements was good (16%); consequently, V(T) had a good retest variability (14%), intersubject variability (26%), and intraclass correlation coefficient (0.89). V(T) increased after 120 min, suggesting an accumulation of radiometabolites in the brain. Radioactivity accumulated in the skull throughout the entire scan but was thought to be an insignificant source of data contamination. CONCLUSION Studies in monkeys facilitated our development and selection of (18)F-FMPEP-d(2), compared with (18)F-FMPEP, as a radioligand demonstrating high brain uptake, high percentage of specific binding, and reduced uptake in bone. Retest analysis in human subjects showed that (18)F-FMPEP-d(2) has greater precision and accuracy than (11)C-MePPEP, allowing smaller sample sizes to detect a significant difference between groups.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Receptor using Positron Emission Tomography

The actions of marijuana (cannabis) are mediated by receptors (primarily the cannabinoid CB1 receptor) that have unusually high density and wide distribution in brain. In addition to mediating the effects of exogenous drugs like cannabis, these receptors also receive signals from endogenous cannabinoids (endocannabinoids), which modulate the release of several other neurotransmitters. Since abn...

متن کامل

In vitro and in vivo evaluation of 11C-SD5024, a novel PET radioligand for human brain imaging of cannabinoid CB1 receptors

We recently developed a novel cannabinoid subtype-1 (CB1) receptor radioligand (11)C-SD5024 for brain imaging. This study aimed to evaluate (11)C-SD5024 both in vitro and in vivo and compare it with the other CB1 receptor ligands previously used in humans, i.e., (11)C-MePPEP, (11)C-OMAR, (18)F-MK-9470, and (18)F-FMPEP-d2. In vitro experiments were performed to measure dissociation constant (Ki)...

متن کامل

[18F]MK-9470, a positron emission tomography (PET) tracer for in vivo human PET brain imaging of the cannabinoid-1 receptor.

[(18)F]MK-9470 is a selective, high-affinity, inverse agonist (human IC(50), 0.7 nM) for the cannabinoid CB1 receptor (CB1R) that has been developed for use in human brain imaging. Autoradiographic studies in rhesus monkey brain showed that [(18)F]MK-9470 binding is aligned with the reported distribution of CB1 receptors with high specific binding in the cerebral cortex, cerebellum, caudate/put...

متن کامل

Effect of Cannabinoid Receptor Activation on Spreading Depression

Objective(s) The objective of this study was to evaluate the effect of cannabinoid on cortical spreading depression (CSD) in rat brain. Cannabis has been used for centuries for both symptomatic and prophylactic treatment of different types of headaches including migraine. CSD is believed to be a putative neuronal mechanism underlying migraine aura and subsequent pain. Materials and Methods T...

متن کامل

Microinjection of WIN55,212-2 as a Cannabinoid Agonist into the Basolateral Amygdala Induces Sensitization to Morphine in Rats

Introduction: Previous studies have shown that the basolateral amygdale (BLA) is rich of CB1 cannabinoid receptors and involved in cannabinoid-induced antinociception. Also, it seems that there are functional interactions between the cannabinoid CB1 and opioid receptors in the process of sensitization to opiates. In the present study, we tried to examine the role of intra-BLA cannabinoid rece...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 51 1  شماره 

صفحات  -

تاریخ انتشار 2010