New Adaptive Reclosing Technique in Unbalanced Distribution System

نویسنده

  • Hun-Chul Seo
چکیده

The conventional reclosing of a distribution system is performed after a fixed dead time. However, it may lead to the increased outage time due to delayed reclosing. To solve this problem, this paper proposes a new adaptive reclosing scheme. The electrostatic induction is analyzed under at during-fault and post-fault conditions. Based on this analysis, the method to judge the fault clearance using the load current is proposed. The reclosing is adaptively performed after fault clearance. The distribution system and reclosing scheme are modelled by the electromagnetic transient program (EMTP). The various simulations according to the unbalanced ratio and various fault conditions are performed and analyzed. The superiority of the proposed scheme is verified by comparing with the conventional reclosing method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

One Terminal Digital Algorithm for Adaptive Single Pole Auto-Reclosing Based on Zero Sequence Voltage

This paper presents an algorithm for adaptive determination of the dead timeduring transient arcing faults and blocking automatic reclosing during permanent faults onoverhead transmission lines. The discrimination between transient and permanent faults ismade by the zero sequence voltage measured at the relay point. If the fault is recognised asan arcing one, then the third harmonic of the zero...

متن کامل

New Configuration and Novel Reclosing Procedure of Distribution System for Utilization of BESS as UPS in Smart Grid

This paper proposes a new configuration and novel reclosing procedure of a distribution system with a battery energy storage system (BESS) used as an uninterruptible power supply (UPS) in a smart grid. The proposed new configurations of the distribution systems are the installation of a circuit breaker (CB) on both sides of the distribution line, the replacement of the recloser with a CB and pr...

متن کامل

Frequency Estimation of Unbalanced Three-Phase Power System using a New LMS Algorithm

This paper presents a simple and easy implementable Least Mean Square (LMS) type approach for frequency estimation of three phase power system in an unbalanced condition. The proposed LMS type algorithm is based on a second order recursion for the complex voltage derived from Clarke's transformation which is proved in the paper. The proposed algorithm is real adaptive filter with real parameter...

متن کامل

Implementation of Fast Adaptive Single-Phase Reclosing Based on Measurement of Harmonic Content in the Real-Time Digital Simulator (RTDS)

This paper presents the implementation of a fast adaptive single-phase reclosing scheme based on the measurement of voltage harmonic content. The main objective of this scheme is to ensure the application of single-phase reclosing after the transient fault extinction or perform automatic blocking maneuver and three-phase tripping for permanent faults. The transmission system represented was bas...

متن کامل

Determining the Optimal Location and Amount of Distributed Generation Sources in an Unbalanced Radial Distribution Grid

Optimal placement of scattered generator sources in the main and secondary feeders of radial grid reduces energy losses, releases the capacity of existing feeders and improves the existing voltage profile. In this project determine the location and suitable for the production of production resources S cattered in radial feeders of unbalanced distribution networks, a new formulation solution is ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017