Stability analysis of a degenerate hyperbolic system modelling a heat exchanger

نویسندگان

  • Michael Hanke
  • K. Henrik
  • A. Olsson
  • Magnus Strömgren
چکیده

Mathematical modelling of a heat exchanger in a carbon dioxide heat pump, an evaporator, is considered. A reduced model, called the the zero Mach-number limit, is derived from the Euler equations of compressible fluid flow through elimination of time scales associated with sound waves. The well-posedness of the resulting partial differentialalgebraic equation (PDAE) is investigated by analysis of a frozen coefficient linearisation as well as by numerical experiments. The linear stability analysis is done through transformation to a canonical form with one hyperbolic component, one parabolic component and one algebraic component. Using this canonical form it is seen how to prescribe boundary and initial data and an energy estimate is derived. Numerical experiments on the nonlinear PDAE using a finite difference spatial discretisation support the linear stability analysis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The perturbation and ADAE index of a degenerated hyperbolic system modelling a heat exchanger

The heat exchanger in a heat pump can be modelled by the zero Mach-number limit of the Euler equations of compressible fluid flow. This system turns out to be a coupled hyperbolic/parabolic equation with coupled, time-dependent boundary conditions. Using the theory of abstract differential-algebraic equations it is shown that the frozen coefficient system has ADAE index 1. Moreover, the much st...

متن کامل

A Double Pipe Heat Exchanger Design and Optimization for Cooling an Alkaline Fuel Cell System

In the presented research, heat transfer of a mobile electrolyte alkaline fuel cell (AFC) (which the electrolyte has cooling role of system) has been considered. Proper control volumes of system with specific qualification have been chosen. Consequently, heat and mass transfer in control volumes have been assessed. Considerations on them and contributed models lead to approve a double tube heat...

متن کامل

Monodromy problem for the degenerate critical points

For the polynomial planar vector fields with a hyperbolic or nilpotent critical point at the origin, the monodromy problem has been solved, but for the strongly degenerate critical points this problem is still open. When the critical point is monodromic, the stability problem or the center- focus problem is an open problem too. In this paper we will consider the polynomial planar vector fields ...

متن کامل

Stability analysis and feedback control of T-S fuzzy hyperbolic delay model for a class of nonlinear systems with time-varying delay

In this paper, a new T-S fuzzy hyperbolic delay model for a class of nonlinear systems with time-varying delay, is presented to address the problems of stability analysis and feedback control. Fuzzy controller is designed based on the parallel distributed compensation (PDC), and with a new Lyapunov function, delay dependent asymptotic stability conditions of the closed-loop system are derived v...

متن کامل

Analytical and comparative investigations on counter flow heat exchanger using computational fluid dynamics

This paper presents a comprehensive and exclusive thermodynamic analysis of counter flow heat exchanger under various operating and geometrical conditions. Analysis system (ANSYS) workbench 14.0 has been used for computational analysis and comparison with previous literature has been carried out in view of variable temperature and mass flow rate of hot and cold fluids. An analytical and statist...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Mathematics and Computers in Simulation

دوره 74  شماره 

صفحات  -

تاریخ انتشار 2007