Dry powder inhaler formulation.

نویسندگان

  • Martin J Telko
  • Anthony J Hickey
چکیده

A drug product combines pharmacologic activity with pharmaceutical properties. Desirable performance characteristics are physical and chemical stability, ease of processing, accurate and reproducible delivery to the target organ, and availability at the site of action. For the dry powder inhaler (DPI), these goals can be met with a suitable powder formulation, an efficient metering system, and a carefully selected device. This review focuses on the DPI formulation and development process. Most DPI formulations consist of micronized drug blended with larger carrier particles, which enhance flow, reduce aggregation, and aid in dispersion. A combination of intrinsic physicochemical properties, particle size, shape, surface area, and morphology affects the forces of interaction and aerodynamic properties, which in turn determine fluidization, dispersion, delivery to the lungs, and deposition in the peripheral airways. When a DPI is actuated, the formulation is fluidized and enters the patient's airways. Under the influence of inspiratory airflow, the drug particles separate from the carrier particles and are carried deep into the lungs, while the larger carrier particles impact on the oropharyngeal surfaces and are cleared. If the cohesive forces acting on the powder are too strong, the shear of the airflow may not be sufficient to separate the drug from the carrier particles, which results in low deposition efficiency. Advances in understanding of aerosol and solid state physics and interfacial chemistry are moving formulation development from an empirical activity to a fundamental scientific foundation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficacy and Tolerability of Fluticasone Propionate/Salmeterol MDI Compared With Concurrent Fluticasone Propionate and Salmeterol MDI in Adult Patients with Persistent Asthma: A Randomized, Double-Blind 12-Week Study

Background: The use of a single inhaler to administer a dry powder formulation of fluticasone (FP) and salmeterol (SM) is at least as effective as concurrent administration of the mono-components from individual dry powder inhalers. Whether the same applies to the pressurised metered dose inhaled (pMDI) formulation of these products which, unlike the dry powder formulations are not breath-actua...

متن کامل

Formulations and Inhaler for Patients on Mechanical Ventilation

Patents: To deliver drugs to patients on mechanical ventilation, the drug particles have to successfully navigate through an endotracheal tube and the ventilator tubing. Liquid formulations (e.g. nebulized) normally used with these patients are inefficient. Large amounts of drugs are deposited in the endotracheal tube and within the ventilator circuit. Dry powders offer an alternative formulati...

متن کامل

Physical characterization of component particles included in dry powder inhalers. I. Strategy review and static characteristics.

The performance of dry powder aerosols for the delivery of drugs to the lungs has been studied extensively in the last decade. The focus for different research groups has been on aspects of the powder formulation, which relate to solid state, surface and interfacial chemistry, bulk properties (static and dynamic) and measures of performance. The nature of studies in this field, tend to be compl...

متن کامل

Pharmaceutical equivalence of the combination formulation of budesonide and formoterol in a single capsule with a dry powder inhaler.

OBJECTIVE To evaluate the pharmaceutical equivalence of a test formulation (fixed-dose combination of budesonide and formoterol fumarate in a single capsule dispensed in an Aerocaps® inhaler) in relation to a reference formulation (budesonide and formoterol fumarate in two separate capsules dispensed in an Aerolizer® inhaler). METHODS This was an in vitro study in which we performed the ident...

متن کامل

Computational fluid dynamics (CFD) assisted performance evaluation of the Twincer™ disposable high-dose dry powder inhaler.

OBJECTIVES To use computational fluid dynamics (CFD) for evaluating and understanding the performance of the high-dose disposable Twincer™ dry powder inhaler, as well as to learn the effect of design modifications on dose entrainment, powder dispersion and retention behaviour. METHODS Comparison of predicted flow and particle behaviour from CFD computations with experimental data obtained wit...

متن کامل

Impact of capsule selection on formulation stability in dry powder inhalers (DPIs)

The delivery of inhalation-based formulations is achieved by devices that fall into three segments: nebulizers, metered dose inhalers (MDIs), and dry powder inhalers (DPIs).2 There is much discussion about which device is most appropriate, though that discussion is well beyond the scope of this article. It is of note however, that MDIs and DPIs have been shown to function equally well when pati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 50 9  شماره 

صفحات  -

تاریخ انتشار 2005