Quantification of [C]-meta-hydroxyephedrine uptake in human myocardium
نویسندگان
چکیده
Background: The aims of this study were to determine the optimal tracer kinetic model for [C]-meta-hydroxyephedrine ([C]HED) and to evaluate the performance of several simplified methods. Methods: Thirty patients underwent dynamic 60-min [C]HED scans with online arterial blood sampling. Single-tissue and both reversible and irreversible two-tissue models were fitted to the data using the metabolite-corrected arterial input function. For each model, reliable fits were defined as those yielding outcome parameters with a coefficient of variation (CoV) <25%. The optimal model was determined using Akaike and Schwarz criteria and the F-test, together with the number of reliable fits. Simulations were performed to study accuracy and precision of each model. Finally, quantitative results obtained using a population-averaged metabolite correction were evaluated, and simplified retention index (RI) and standardized uptake value (SUV) results were compared with quantitative volume of distribution (VT) data. Results: The reversible two-tissue model was preferred in 75.8% of all segments, based on the Akaike information criterion. However, VT derived using the single-tissue model correlated highly with that of the two-tissue model (r 2 = 0.94, intraclass correlation coefficient (ICC) = 0.96) and showed higher precision (CoV of 24.6% and 89.2% for singleand two-tissue models, respectively, at 20% noise). In addition, the single-tissue model yielded reliable fits in 94.6% of all segments as compared with 77.1% for the reversible two-tissue model. A population-averaged metabolite correction could not be used in approximately 20% of the patients because of large biases in VT. RI and SUV can provide misleading results because of non-linear relationships with VT. Conclusions: Although the reversible two-tissue model provided the best fits, the single-tissue model was more robust and results obtained were similar. Therefore, the single-tissue model was preferred. RI showed a non-linear correlation with VT, and therefore, care has to be taken when using RI as a quantitative measure.
منابع مشابه
Quantification of [11C]-meta-hydroxyephedrine uptake in human myocardium
BACKGROUND The aims of this study were to determine the optimal tracer kinetic model for [(11)C]-meta-hydroxyephedrine ([(11)C]HED) and to evaluate the performance of several simplified methods. METHODS Thirty patients underwent dynamic 60-min [(11)C]HED scans with online arterial blood sampling. Single-tissue and both reversible and irreversible two-tissue models were fitted to the data usin...
متن کاملNoninvasive Quantification of Myocardial 11C-Meta-Hydroxyephedrine Kinetics.
UNLABELLED (11)C-meta-hydroxyephedrine ((11)C-HED) kinetics in the myocardium can be quantified using a single-tissue-compartment model together with a metabolite-corrected arterial blood sampler input function (BSIF). The need for arterial blood sampling, however, limits clinical applicability. The purpose of this study was to investigate the feasibility of replacing arterial sampling with ima...
متن کاملCorrelation between scintigraphic evidence of regional sympathetic neuronal dysfunction and ventricular refractoriness in the human heart.
BACKGROUND Denervation supersensitivity has been proposed as a mechanism for the relation between ventricular arrhythmias and the sympathetic nervous system. Evaluation of this phenomenon in humans has become feasible only recently with the development of noninvasive scintigraphic methods for evaluating the pattern of sympathetic innervation. The purpose of this study was to determine if scinti...
متن کاملRelationship between altered sympathetic innervation, oxidative metabolism and contractile function in the cardiomyopathic human heart; a non-invasive study using positron emission tomography.
AIMS To identify functional and metabolic correlates of impaired presynaptic sympathetic innervation in the cardiomyopathic human heart using non-invasive correlative imaging. METHODS AND RESULTS In 10 patients with idiopathic dilated cardiomyopathy, presynaptic catecholamine uptake sites were quantified by positron emission tomography with C-11 hydroxyephedrine. Oxidative metabolism was meas...