Improved T1 fitting with the MOLLI sequence

نویسندگان

  • Mitchell A Cooper
  • Thanh Nguyen
  • Pascal Spincemaille
  • Jonathan D Kochav
  • Martin R Prince
  • Jonathan W Weinsaft
  • Yi Wang
چکیده

Background T1 mapping has great potential for diagnosing diffuse cardiomyopathies. Modified Look Locker Inversion Recovery (MOLLI) is a promising 2D SSFP technique to measure T1 differences between healthy and diseased states in cardiac tissue. However, this method has been found to provide variable T1 values at different flip angles. Here we develop an improved fitting algorithm which accounts for the imperfect RF flip angle profile and SSFP signal evolution in MOLLI. We show that significantly improved T1 accuracy can be achieved across a larger range of flip angle in human calf muscle. This algorithm is then applied to MOLLI data obtained in the heart using an optimized flip angle.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

How Accurate Is MOLLI T1 Mapping In Vivo? Validation by Spin Echo Methods

T1 mapping is a promising quantitative tool for assessing diffuse cardiomyopathies. The purpose of this study is to quantify in vivo accuracy of the Modified Look-Locker Inversion Recovery (MOLLI) cardiac T1 mapping sequence against the spin echo gold standard, which has not been done previously. T1 accuracy of MOLLI was determined by comparing with the gold standard inversion recovery spin ech...

متن کامل

Free-breathing post-contrast three-dimensional T1 mapping: Volumetric assessment of myocardial T1 values.

PURPOSE To develop a three-dimensional (3D) free-breathing myocardial T1 mapping sequence for assessment of left ventricle diffuse fibrosis after contrast administration. METHODS In the proposed sequence, multiple 3D inversion recovery images are acquired in an interleaved manner. A mixed prospective/retrospective navigator scheme is used to obtain the 3D Cartesian k-space data with fully sam...

متن کامل

Bloch Equations-Based Reconstruction of Myocardium T1 Maps from Modified Look-Locker Inversion Recovery Sequence

Modified Look-Locker Inversion recovery (MOLLI) sequence is increasingly performed for myocardial T1 mapping but is known to underestimate T1 values. The aim of the study was to quantitatively analyze several sources of errors when T1 maps are derived using standard post-processing of the sequence and to propose a reconstruction approach that takes into account inversion efficacy (η), T2 relaxa...

متن کامل

Instantaneous signal loss simulation (InSiL): an improved algorithm for myocardial T₁ mapping using the MOLLI sequence.

PURPOSE To propose a T1 mapping algorithm for the modified Look-Locker inversion-recovery (MOLLI) sequence that can improve T1 estimation accuracy. MATERIALS AND METHODS The modified T1 mapping algorithm (InSiL) is based on the simulation of MOLLI signal evolution and simulates the longitudinal magnetization signal perturbation by each single-shot image acquisition in MOLLI as an instantaneou...

متن کامل

Improved precision in SASHA T1 mapping with a variable flip angle readout

Background The SAturation-recovery single-SHot Acquisition (SASHA) T1 mapping sequence has excellent accuracy independent of T1, T2, heart rate, and flip angle [1], which are known dependencies of the more commonly used MOdified Look-Locker Inversion-recovery (MOLLI) sequence. However, SASHA has a greater T1 variability (poorer precision) compared to MOLLI. A two-parameter fit, with assumed ide...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2013