Nonoptical determinants of aniseikonia.

نویسندگان

  • A Bradley
  • J Rabin
  • R D Freeman
چکیده

Interocular differences in apparent size (aniseikonia) are typically associated with interocular differences in refractive error (anisometropia). Aniseikonia is generally thought to reflect disparities in retinal image size that often accompany anisometropia. This assumption was examined with seven highly anisometropic subjects who were tested under conditions in which no substantial retinal image size differences were present. Using a dichoptic size matching task, consistent and large (mean = 22%) aniseikonias were found. Myopic anisometropes exhibit perceptual minification, while hyperopes demonstrate perceptual magnification when using their more ametropic eye. Both ultrasonic and fundus examinations of these subjects indicate that differential retinal growth or stretching is responsible for these findings.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Differences in tests of aniseikonia.

The New Aniseikonia Test (NAT), a hand-held direct-comparison test using red/green anaglyphs, has several potential advantages as a screener. We compared the validity of the NAT to that of the Space Eikonometer in three experiments: (1) aniseikonia was induced by calibrated size lenses in a double-blind study of 15 normal subjects; (2) habitual aniseikonia was measured with both instruments in ...

متن کامل

The evaluation of two new computer-based tests for measurement of Aniseikonia.

PURPOSE To evaluate the accuracy and repeatability of size lens induced aniseikonia measurement with the Aniseikonia Inspector Version 1 and a newer customized version of the Aniseikonia Inspector, Version 2. METHODS Aniseikonia was measured on 27 subjects with both versions of the Aniseikonia Inspector in normal room illumination. Measurements of induced aniseikonia were made using size lens...

متن کامل

Differences in Tests of Aniseikonio

The New Aniseikonia Test (NAT), a hand-held direct-comparison test using red/green anaglyphs, has several potential advantages as a screener. We compared the validity of the NAT to that of the Space Eikonometer in three experiments: (1) aniseikonia was induced by calibrated size lenses in a doubleblind study of 15 normal subjects; (2) habitual aniseikonia was measured with both instruments in f...

متن کامل

SCIENTIFIC REPORT Aniseikonia associated with epiretinal membranes

Aims: To determine whether the computerised version of the new aniseikonia test (NAT) is a valid, reliable method to measure aniseikonia and establish whether aniseikonia occurs in patients with epiretinal membranes (ERM) with preserved good visual acuity. Methods: With a computerised version of the NAT, horizontal and vertical aniseikonia was measured in 16 individuals (mean 47 (SD 16.46) year...

متن کامل

Predicting refractive aniseikonia after cataract surgery in anisometropia.

PURPOSE To propose a comprehensive classification of anisometropia, a method to calculate the theoretical related aniseikonia (objective aniseikonia) and a purpose-designed eikonometer to measure aniseikonia psychophysically (subjective aniseikonia). SETTING University Hospital Antwerp, Department of Ophthalmology, Edegem, Belgium. METHODS The occurrence of anisometropia was evaluated in 26...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 24 4  شماره 

صفحات  -

تاریخ انتشار 1983