How Effective Are Radiation Reducing Gloves in C-arm Fluoroscopy-guided Pain Interventions?

نویسندگان

  • Ah Na Kim
  • Young Jae Chang
  • Bo Kyung Cheon
  • Jae Hun Kim
چکیده

BACKGROUND The physician's hands are close to the X-ray field in C-arm fluoroscopy-guided pain interventions. We prospectively investigated the radiation attenuation of Proguard RR-2 gloves. METHODS In 100 cases, the effective doses (EDs) of two dosimeters without a radiation-reducing glove were collected. EDs from the two dosimeters-one dosimeter wrapped with a glove and the other dosimeter without a glove- were also measured at the side of the table (Group 1, 140 cases) and at a location 20 cm away from the side of the table (Group 2, 120 cases). Mean differences such as age, height, weight, radiation absorbed dose (RAD), exposure time, ED, and ratio of EDs were analyzed. RESULTS In the EDs of two dosimeters without gloves, there were no significant differences (39.0 ± 36.3 µSv vs. 38.8 ± 36.4 µSv) (P = 0.578). The RAD (192.0 ± 182.0 radcm(2)) in Group 2 was higher than that (132.3 ± 103.5 radcm(2)) in Group 1 (P = 0.002). The ED (33.3 ± 30.9 µSv) of the dosimeter without a glove in Group 1 was higher than that (12.3 ± 8.8 µSv) in Group 2 (P < 0.001). The ED (24.4 ± 22.4 µSv) of the dosimeter wrapped with a glove in Group 1 was higher than that (9.2 ± 6.8 µSv) in Group 2 (P < 0.001). No significant differences were noted in the ratio of EDs (73.5 ± 6.7% vs. 74.2 ± 9.3%, P = 0.469) between Group 1 and Group 2. CONCLUSIONS Proguard RR-2 gloves have a radiation attenuation effect of 25.8-26.5%. The radiation attenuation is not significantly different by intensity of scatter radiation or the different RADs of C-arm fluoroscopy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation Safety for Pain Physicians: Technique or Equipment

This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http:// creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. Anatomic landmarks are useful for simple interven-tional techniques in pain clinics. Howe...

متن کامل

The Radiation Exposure of Radiographer Related to the Location in C-arm Fluoroscopy-guided Pain Interventions

BACKGROUND Although a physician may be the nearest to the radiation source during C-arm fluoroscope-guided interventions, the radiographer is also near the fluoroscope. We prospectively investigated the radiation exposure of radiographers relative to their location. METHODS The effective dose (ED) was measured with a digital dosimeter on the radiographers' left chest and the side of the table...

متن کامل

Radiation Safety and Education in the Applicants of the Final Test for the Expert of Pain Medicine

BACKGROUND The C-arm fluoroscope is known as the most important equipment in pain interventions. This study was conducted to investigate the completion rate of education on radiation safety, the knowledge of radiation exposure, the use of radiation protection, and so on. METHODS Unsigned questionnaires were collected from the 27 pain physicians who applied for the final test to become an expe...

متن کامل

C-Arm Fluoroscope Angle Settings for Fluoroscopically Guided Lumbar Transforaminal Epidural Injections.

BACKGROUND DATA Minimizing fluoroscopy time in spine interventions is critical for time of procedure as well as radiation safety of the patient and medical personnel. Specific fluoroscopy angle settings for fluoroscopically guided L4-S1 transforaminal epidural injections (TFEIs) have not been described. OBJECTIVES To describe the most common encountered settings for the C-arm fluoroscope angl...

متن کامل

Treatment of vertebral body compression fractures using percutaneous kyphoplasty guided by a combination of computed tomography and C-arm fluoroscopy with finger-touch guidance to determine the needle entry point.

This study aimed to evaluate the results and complications of image-guided percutaneous kyphoplasty (PKP) using computed tomography (CT) and C-arm fluoroscopy, with finger-touch guidance to determine the needle entry point. Of the 86 patients (106 PKP) examined, 56 were treated for osteoporotic vertebral compression fractures and 30 for vertebral tumors. All patients underwent image-guided trea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 27  شماره 

صفحات  -

تاریخ انتشار 2014