TU-C-17A-11: Progressive Knowledge Modeling for Pelvic IMRT/VMAT Treatment Planning.

نویسندگان

  • S Lu
  • L Yuan
  • O Craciunescu
  • Y Ge
  • F Yin
  • Q Wu
چکیده

PURPOSE To investigate the feasibility of progressive knowledge modeling for IMRT/VMAT treatment planning for multiple cancer types in the pelvic region. METHODS The treatment planning knowledge model quantifies correlations between patient anatomical features and the OAR dose sparing features. The model is trained with prior plans using a stepwise regression machine learning technique. The progressive modeling process starts with 20 low risk prostate plans (type 1) which offer simplest PTV-OAR geometry. Cases with more complex PTV-OAR anatomies (prostate with lymph node, type 2 and anal rectal, type 3) are added to the training dataset one by one until the model prediction accuracies reach a plateau. The starting point of the plateau also defines the minimum numbers of type 2 and 3 training cases required for modelling. The DVHs predicted by the knowledge model for bladder, femoral heads and rectum were validated by 20, 9 and 18 cases with type 1, 2, and 3 geometries, respectively (rectum DVHs are omitted for type 3). Mean and standard deviation of differences between the dosimetric parameters sampled from the DVHs and the corresponding actual plan values measure the prediction accuracy of the model. Further, the accuracy was also compared with the single-type models which were trained by single type cases. RESULTS Prediction accuracy reaches plateau when 6 type 2 and 8 type 3 cases were added to the training dataset. The determination coefficients R2 (should be square, font) for the OARs are: Bladder 0.90, rectum 0.64, and femoral heads 0.82. The prediction accuracies by the multiple-type model and single-type model have no significant differences by F-test (p-value: bladder: 0.58, femoral head: 0.44, rectum: 0.97). CONCLUSION Progressive knowledge modeling of OAR sparing for multiple cancer types in pelvic region is feasible and has comparable accuracy to single cancer type modeling. Partially supported by NIH/NCI under grant #R21CA161389 and a master research grant by Varian Medical System.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol

Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...

متن کامل

Comparative study on dosimetry of VMAT and IMRT in assisted radiotherapy after radical resection of rectal cancer

The present study compared the dosimetric differences of volumetric modulated arc therapy (VMAT) and 7-field intensity modulated radiation therapy technology (7F-IMRT) in assisted radiotherapy plan after resection of rectal carcinoma. Ten cases of patients at stages II-III of rectal cancer transabdominal resection with postoperative pelvic radiotherapy underwent 7F-IMRT and VMAT radiotherapy pl...

متن کامل

A dosimetric comparison of volumetric modulated arc therapy (VMAT) and non-coplanar intensity modulated radiotherapy (IMRT) for nasal cavity and paranasal sinus cancer

BACKGROUND To compare dosimetric parameters of volumetric modulated arc therapy (VMAT) and non-coplanar intensity modulated radiotherapy (IMRT) for nasal cavity and paranasal sinus cancer with regard to the coverage of planning target volume (PTV) and the sparing of organs at risk (OAR). METHODS Ten patients with nasal cavity or paranasal sinus cancer were re-planned by VMAT (two-arc) plan an...

متن کامل

Application of AAPM TG 119 to volumetric arc therapy (VMAT)

The purpose of this study was to create AAPM TG 119 benchmark plans for volumetric arc therapy (VMAT) and to compare VMAT plans with IMRT plan data. AAPM TG 119 proposes a set of test clinical cases for testing the accuracy of IMRT planning and delivery system. For these test cases, we generated two treatment plans, the first plan using 7-9 static dMLC IMRT fields and a second plan utilizing on...

متن کامل

Optimization of prostate cancer radiotherapy using of a spacer gel, volumetric modulated arc therapy and a single biological organ at risk objective

Background: The aim was to evaluate the benefit of technical advances for treatment planning: introduction of a hydrogel spacer, VMAT (volumetric modulated arc therapy) and a single biological organ at risk objective for the rectum and bladder. Initial standard was a step-and-shoot IMRT (intensity modulated radiotherapy) without a spacer and conventional organ at risk objectives.  Material...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical physics

دوره 41 6  شماره 

صفحات  -

تاریخ انتشار 2014