Integration of a Hard X-ray Microprobe with a Diffractometer for Microdiffraction
نویسندگان
چکیده
A hard x-ray Fresnel zone-plate-based microprobe has been designed and integrated into a Newport kappa diffractometer for microdiffraction studies at the 2ID-D beamline at the Advance Photon Source. The microprobe employs 10 cm and 40 cm (focal length at 8 keV) zone plates to provide high and moderate focusing power, respectively. Each zone-plate assembly has two identical zone plates stacked together to provide higher focusing efficiency for higher energy (30 keV) applications. The mounting base of the microprobe is supported by the side of the base of the diffractometer at one end and the central table of the diffractometer at the other end, thus minimizing the instability of relative positions between the focal spot and the specimen. A x-ray focal spot size smaller than 360 nm and angular repeatability of the sample circles smaller than 0.001 deg. have been demonstrated with this setup.
منابع مشابه
X-ray microdiffraction and urine: a new analysis method of crystalluria.
The qualitative and quantitative analyses of crystalluria have clinical significance in the diagnosis and prognosis of urolithiasis. The aim of this paper is to provide a new accurate methodology to get qualitative and quantitative data on urine particulate in patients with renal stone disease.The procedure involves a urine collection, the separation of the solid residual by centrifugation, and...
متن کاملA `beam-selection' high-resolution X-ray diffractometer
A new diffractometer that can be described as a high-intensity low-background high-resolution diffractometer for analysing perfect, nearly perfect and highly imperfect materials on a routine basis is presented. The instrumentation is very simple and uncomplicated, yet the way in which it works is less obvious. The sample requires minimal sample alignment, the resolution can be adjusted to optim...
متن کاملمقایسه گسیل یونی و پرتوی ایکس سخت بین نیتروژن و آرگون در دستگاه پلاسمای کانونی نوع مدر
In this study, some characteristics of a Mather type Plasma Focus (PF) device such as a discharge current, pinch time, ion flux and hard x-ray intensity has been investigated simultaneously in argon and nitrogen gases separately for various operating gas pressures and charging voltages of capacitor bank. It was observed that pinch phenomena was energy and pressure dependent in current sheath as...
متن کاملElectron Microprobe Analysis in Guided Tissue Regeneration: A Case Report
OBJECTIVES Several procedures have been advocated as regenerative procedures in periodontology, but one of the most widely used techniques up to now is guided tissue regeneration (GTR). Likewise, different assessment methods based on clinical, radiographic or histological measurements have been proposed for the evaluation of these regenerative procedures. However, none of the methods used for h...
متن کاملبررسی فازی ترکیبات Mo + 2(1 - x) Si + 2xAl
X-ray powder diffraction data for Mo2.85Al1.91Si4.81 are presented here. The new Mo2.85Al1.91Si4.81 compound was successfully prepared, using the self-propagating high-temperature synthesis (SHS) technique. The starting atomic mixture of reactant powders was Mo + 2(1 - x)Si + 2xAl with 0.2 ≤ x ≤ 0.5. The final powder compound obtained by the SHS technique was determined to be in x = 0.2; Mo(Si,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -