Sunlight Glinting from Water: not a hazard for WFC3 IR
نویسنده
چکیده
We analyze the potential hazard of an HST instrument inadvertently observing a glint of sunlight reflected from water. During nominal operation, the detectors are protected from such illumination. However, because of an anomaly on HST in which the instruments were not commanded to their safe conditions, we wondered what could happen in worst-case scenarios. This report examines one such scenario: what is the likelihood and potential effect on WFC3’s IR detector if HST were to observe sunlight glinting from water? As the irradiance on the detector from a (flat) sea-surface glint potentially could be more than a thousand times greater than that of the reflection from clouds, which we also derive and compare to NICMOS observations, and because the likelihood of HST aiming at such a glint is not entirely negligible, we proposed a groundbased test on a flight-like detector. GSFC persons performed a test similar to the one proposed herein, with no apparent damage to the tested IR detector, which was similar to the WFC3 IR flight array.
منابع مشابه
First On-orbit Measurements of the WFC3-IR Count-rate Non-Linearity
Previous HgCdTe detectors on HST have suffered from a count-rate dependent non-linearity, motivating an investigation of a similar effect on the WFC3-IR detector. An initial measurement of this effect was made by comparing the photometry of star clusters observed over a wide dynamic range and at overlapping wavelengths in WFC3-IR and NICMOS and/or ACS-WFC. Utilizing a color term to account for ...
متن کاملAn Independent Determination of WFC3-IR Zeropoints and Count Rate Non-Linearity from 2MASS Asterisms
We report the results from the CAL/WFC3 program 12335 to constrain the effect of count-rate non-linearity on the WFC3-IR detector by comparing the fluxes of 24 bright stars in asterisms observed with WFC3-IR and 2MASS. An incidental finding is an underestimate of the sample time of the first read for WFC3-IR (i.e., the zeroeth read) which is used to determine photometry for bright sources reach...
متن کاملWFC3 TV2 Testing: IR Intrapixel sensitivity
We derive an approximate intrapixel sensitivity variation (IPSV) of the IR-1 detector of WFC3 from ground-test imagery. The purpose was to assess whether additional testing of this sort should be performed in Thermal Vacuum 3 (TV3) testing, scheduled to commence in February 2008. Whereas NICMOS exhibits IPSV as large as 40%, peak to valley, in the photometry of stars observed in J band with the...
متن کاملWFC3 TV2 Testing: IR Channel Throughput
A new IR detector (IR1; FPA129) was housed in WFC3 during the most recent campaign of thermal vaccum (TV) ground testing at GSFC. We performed measurements of the IR channel throughput over the course of ground testing, and found that the throughput is near expectations on the blue end of the IR channel wavelength range, but approximately 20% lower than expectations on the red end. This is in c...
متن کاملWFC3 SMOV Proposal 11451: The Photometric Performance and Calibration of WFC3/IR
We present the first on-orbit observations to characterize the photometric performance of the infrared (IR) camera on WFC3, based on data collected during the Servicing Mission Orbital Verification 4 Phase (SMOV4) shortly after the installation of the WFC3 instrument on HST. The photometric zero points and stability of the detector are measured in all 15 IR filters, using two different HST spec...