Novel method of predicting the optimal atrioventricular delay in patients with complete AV block, normal left ventricular function and an implanted DDD pacemaker.

نویسندگان

  • Yuko Miki
  • Toshiyuki Ishikawa
  • Kohei Matsushita
  • Youhei Yamakawa
  • Katsumi Matsumoto
  • Shinichi Sumita
  • Kazuaki Uchino
  • Kazuo Kimura
  • Satoshi Umemura
چکیده

BACKGROUND The optimal atrioventricular (AV) delay setting is important for achieving optimal AV synchrony in patients with an implanted DDD pacemaker. Using pulsed Doppler echocardiography is the most common method of predicting the optimal AV delay, but it is a complicated and time-consuming method. Therefore, an automatic optimizing function of the AV delay at different atrial rates is desirable for achieving a favorable hemodynamic state. This study aimed to predict the optimal AV delay using phonocardiography. METHODS AND RESULTS The amplitude of the first heart sound (S1) recorded on the phonocardiogram was measured with different AV delays in 6 patents with complete AV block, normal left ventricular function and an implanted DDD pacemaker. The correlation between the amplitude of S1 and the length of the AV delay was a cubic curve (y=974.15x(3)-23.084x(2)-8.0074x+0.7495, R2=0.9511). The length of the AV delay at the inflection point of the curve showed a significant positive correlation with the optimal AV delay determined by pulsed Doppler echocardiography (R=0.9254, P<0.01). CONCLUSIONS This study demonstrated a novel simple method of predicting the optimal AV delay using phono-cardiography.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated functional imaging in atrioventricular delay time optimisation in patients with dual chamber pacemakers.

BACKGROUND Optimisation of atrioventricular (AV) delay time has positive effects on left ventricular (LV) functions in patients with a DDD pacemaker. However, the method used for optimisation is still debated. AIM To evaluate the effect of different AV delay times on various LV systolic performances by using automated functional imaging (AFI) in patients with a DDD pacemaker and preserved LV ...

متن کامل

Programming an optimal atrioventricular interval in a dual chamber pacemaker regional population.

BACKGROUND Since the introduction of the dual chamber pacemaker (DDDR) in the early 1980s, researchers have repeatedly discussed and attempted to optimize the atrioventricular (AV) interval, in order to increase the cardiac performance of pacemaker patients. Nominal AV delay in a DDDR is not, by hemodynamics, the best option for the majority of patients with AV conduction disorders. Our researc...

متن کامل

Echocardiographic AV-interval optimization in patients with reduced left ventricular function

BACKGROUND Ritter's method is a tool used to optimize AV delay in DDD pacemaker patients with normal left ventricular function only. The goal of our study was to evaluate Ritter's method in AV delay-interval optimization in patients with reduced left ventricular function. METHODS Patients with implanted DDD pacemakers and AVB III degrees were assigned to one of two groups according to ejectio...

متن کامل

Definition of the Optimal Atrioventricular Delay by Simultaneous Measurement of Electrocardiographic and Doppler Echocardiographic Parameters

In atrioventricular (AV) block patients, AV synchrony can be restored by implanting DDD pacing systems if an individual optimization of the pacemaker AV delay is performed. If the latter is neglected and the AV delay is left at nominal settings, adverse hemodynamic effects may develop. Therefore, several methods were proposed to calculate or to estimate the individual hemodynamically optimal le...

متن کامل

Marked First-Degree Atrioventricular Block: A New Indication for Cardiac Pacing

S chüller and Brandt 1 defined the pacemaker syndrome in terms of “symptoms and signs present in the pacemaker patient which are caused by inadequate timing of atrial and ventricular contractions”. This characterization also applies to patients without an implanted pacemaker when “inadequate timing of atrial and ventricular contractions” causes a similar hemodynamic derangement. Thus isolated m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation journal : official journal of the Japanese Circulation Society

دوره 73 4  شماره 

صفحات  -

تاریخ انتشار 2009