A 0.5 μA/Channel front-end for implantable and external ambulatory ECG recorders

نویسندگان

  • Yasser Rezaeiyan
  • Milad Zamani
  • Omid Shoaei
  • Wouter A. Serdijn
چکیده

There is an increasing demand for low power, low voltage, and small size analog readout bio-potential systems. This paper presents an analog front-end for measuring the intra-cardiac signals in implantable and also external ambulatory ECG cardiac recording applications. The analog front-end benefits from voltage to frequency conversion without conventional analog to digital conversion and thereby achieves a very low power consumption. The frequency averaging digital reconstruction makes an intrinsic low pass filter of which the cut-off frequency changes with the averaging interval and eliminates the need for an analog filter in this system. Furthermore, this feature enables the development of a general purpose analog readout bio-potential measurement system with programmable bandwidth. The proposed IC is fabricated in a 0.18 μm CMOS process and occupies 0.396mm2. It can measure intra-cardiac bio-potentials with 9.2-bit resolution while consuming just 0.5 μA per channel from a 1 V supply. The input referred noise of the intra-cardiac signal readout channel is 2 μVrms.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Low-Power CMOS Analog Front-End IC with Adjustable On-Chip Filters for Biosensors

This paper presents a low-power CMOS analog front-end (AFE) IC designed with a selectable on-chip dual AC/DCcoupled paths for bio-sensor applications. The DC-coupled path can be selected to sense a biosignal with useful DC information, and the AC-coupled path can be selected for sensing the AC content of the biosignal by attenuating the unwanted DC component. The AFE IC includes a DC-coupled in...

متن کامل

Concept Design for a 1-Lead Wearable/Implantable ECG Front-End: Power Management

Power supply quality and stability are critical for wearable and implantable biomedical applications. For this reason we have designed a reconfigurable switched-capacitor DC-DC converter that, aside from having an extremely small footprint (with an active on-chip area of only 0.04 mm²), uses a novel output voltage control method based upon a combination of adaptive gain and discrete frequency s...

متن کامل

Time-Domain Response of ECG Bioelectric Amplifiers

This paper investigates the low-frequency response of a multi-stage bioelectric amplifier intended for use in the measurement of the electrocardiogram (ECG) using dry contact electrodes. These electrodes have an impedance which is typically an order of magnitude greater than that of the standard disposable self-adhesive electrodes used in clinical ECG recording. The design was undertaken with t...

متن کامل

Use of implantable and external loop recorders in syncope with unknown causes

The gold standard for diagnosing syncope is to elucidate the symptom-electrocardiogram (ECG) correlation. The ECG recordings during syncope allow physicians to either confirm or exclude an arrhythmia as the mechanism of syncope. Many studies have investigated the use of internal loop recorder (ILR), while few studies have used external loop recorder (ELR) for patients with unexplained syncope. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Microelectronics Journal

دوره 74  شماره 

صفحات  -

تاریخ انتشار 2018