Analysis of intact phosphoinositides in biological samples.

نویسندگان

  • Trevor R Pettitt
  • Stephen K Dove
  • Anneke Lubben
  • Simon D J Calaminus
  • Michael J O Wakelam
چکیده

It is now apparent that each of the known, naturally occurring polyphosphoinositides, the phosphatidylinositol monophosphates (PtdIns3P, PtdIns4P, PtdIns5P), phosphatidylinositol bisphosphates [PtdIns(3,4)P(2), PtdIns(3,5)P(2), PtdIns(4,5)P(2)], and phosphatidylinositol trisphosphate [PtdIns(3,4,5)P(3)], have distinct roles in regulating many cellular events, including intracellular signaling, migration, and vesicular trafficking. Traditional identification techniques require [(32)P]inorganic phosphate or [(3)H]inositol radiolabeling, acidified lipid extraction, deacylation, and ion-exchange head group separation, which are time-consuming and not suitable for samples in which radiolabeling is impractical, thus greatly restricting the study of these lipids in many physiologically relevant systems. Thus, we have developed a novel, high-efficiency, buffered citrate extraction methodology to minimize acid-induced phosphoinositide degradation, together with a high-sensitivity liquid chromatography-mass spectrometry (LC-MS) protocol using an acetonitrile-chloroform-methanol-water-ethylamine gradient with a microbore silica column that enables the identification and quantification of all phosphoinositides in a sample. The liquid chromatograph is sufficient to resolve PtdInsP(3) and PtdInsP(2) regioisomers; however, the PtdInsP regioisomers require a combination of LC and diagnostic fragmentation to MS(3). Data are presented using this approach for the analysis of phosphoinositides in human platelet and yeast samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Systematic analysis of main constituents in rat biological samples after oral administration of the methanol extract of Fructus Aurantii by HPLC-ESI-MS/MS

High performance liquid chromatography (HPLC) with diode array detection (DAD) and electrospray ionization tandem mass spectrometry (ESI/MS/MS) was used to analyze the main components in the methanol extract of Fructus Aurantii (FA) and the metabolites in rat biological samples after oral administration of the methanol extract of FA. There were 31 constituents identified in the extract of FA in...

متن کامل

Systematic analysis of main constituents in rat biological samples after oral administration of the methanol extract of Fructus Aurantii by HPLC-ESI-MS/MS

High performance liquid chromatography (HPLC) with diode array detection (DAD) and electrospray ionization tandem mass spectrometry (ESI/MS/MS) was used to analyze the main components in the methanol extract of Fructus Aurantii (FA) and the metabolites in rat biological samples after oral administration of the methanol extract of FA. There were 31 constituents identified in the extract of FA in...

متن کامل

3D Characterization of Uniaxial Compressive Strength of Transversely-Isotropic Intact Rocks

The uniaxial compressive strength (UCS) of intact rocks is one of the key parameters in the course of site characterizations. The isotropy/anisotropy condition of the UCS of intact rocks is dependent on the internal structure of the rocks. The rocks with a random grain structure exhibit an isotropic behavior. However, the rocks with a linear/planar grain structure generally behave transversely-...

متن کامل

Developing Preparation Methods for Biological Samples to Determine Trace Amounts of Heavy Metals: A Review Study

Introduction: Perpetration of samples is one of the most important stages needed for trace residue analysis of biological specimens when human exposure assessment is required. The samples preparation process makes the analyte get more purified and enriched as well as more compatible to the analysis instrument systems. The present study has concentrated on a systematic review of different articl...

متن کامل

Microchip Ce-esi-ms for the Separation of Biological Samples

We have developed a new MS compatible coating strategy to reduce electroosmotic flow (EOF) to a near zero value, which results in high resolution, high efficiency CE separations of biological samples. Utilizing this strategy for microfluidic CE-ESI-MS makes analysis of small molecules to intact proteins feasible using a single device platform. The exceptional performance of these devices has en...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of lipid research

دوره 47 7  شماره 

صفحات  -

تاریخ انتشار 2006