Effects of image reconstruction algorithm on neurotransmission PET studies in humans: comparison between filtered backprojection and ordered subsets expectation maximization.

نویسندگان

  • Takuya Morimoto
  • Hiroshi Ito
  • Akihiro Takano
  • Yoko Ikoma
  • Chie Seki
  • Takashi Okauchi
  • Katsuyuki Tanimoto
  • Akira Ando
  • Takahiro Shiraishi
  • Taiga Yamaya
  • Tetsuya Suhara
چکیده

OBJECTIVES Both reconstruction algorithms, filtered backprojection (FBP) and ordered subsets expectation maximization (OSEM), are widely used in clinical positron emission tomography (PET) studies. Image reconstruction for most neurotransmission PET scan data is performed by FBP, while image reconstruction for whole-body [18F]FDG scan data is usually performed by OSEM. Although several investigators have compared FBP and OSEM in terms of the quantification of regional radioactivity and physiological parameters calculated from PET data, only a few studies have compared the two reconstruction algorithms in PET studies that estimate neurotransmission, i.e., neuroreceptor and neurotransporter binding. In this study we compared mean regional radioactivity concentration in the late phase and binding potential (BP) between FBP and OSEM algorithms in neurotransmission PET studies for [11C]raclopride and [11C]DASB. METHODS Dynamic PET scans with [11C]raclopride in 3-dimensional mode were performed on seven healthy subjects. Dynamic PET scans with [11C]DASB in 2-dimensional mode were performed on another seven subjects. OSEM images were post-filtered so that its transverse spatial resolution became similar to that of FBP with the same Hanning filter (Kernel FWHM 6 mm). In both PET studies we calculated the BP of [11C]raclopride and [11C]DASB by a reference tissue model for each ROI (region of interest). RESULTS There was no significant difference in mean regional radioactivity concentration between FBP and OSEM for [11C]raclopride and [11C]DASB. Only +2.4 - +3.2%, but still a significant difference in BP of [11C]raclopride between FBP and OSEM was observed in the striatum. There was no significant difference in BP between FBP and OSEM in other than the striatum for [11C]raclopride and in all regions for [11C]DASB. In addition, there was no significant difference in root mean square error between FBP and OSEM when BP was calculated. CONCLUSIONS The BP values were similar between FBP and OSEM algorithms with [11C]raclopride and [11C]DASB. This study indicates that OSEM can be used for human neurotransmission PET studies for calculating BP although OSEM was not necessarily superior to FBP in the present study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of parametric FBP and OS-EM reconstruction algorithm images for PET dynamic study.

An ordered subsets expectation maximization (OS-EM) algorithm is used for image reconstruction to suppress image noise and to make non-negative value images. We have applied OS-EM to a digital brain phantom and to human brain 18F-FDG PET kinetic studies to generate parametric images. A 45 min dynamic scan was performed starting injection of FDG with a 2D PET scanner. The images were reconstruct...

متن کامل

Comparison of a noise-weighted filtered backprojection algorithm with the Standard MLEM algorithm for poisson noise.

Iterative maximum-likelihood expectation maximization and ordered-subset expectation maximization algorithms are excellent for image reconstruction and usually provide better images than filtered backprojection (FBP). Recently, an FBP algorithm able to incorporate noise weighting during reconstruction was developed. This paper compares the performance of the noise-weighted FBP algorithm and the...

متن کامل

Impact of reconstruction method on quantitative parameters of 99mTc-TRODAT-1 SPECT

Introduction: Quantitative evaluation is recommended to improve diagnostic ability and serial assessment of dopamine transporter (DAT) density scans. We decided to compare the ordered subsets expectation-maximization (OSEM) with filtered back-projection (FBP), and to investigate the impact of different iteration and cut-off frequencies on SBR values. Methods</stro...

متن کامل

A non-parametric bootstrap approach for analysing the statistical properties of SPECT and PET images.

Knowledge of the statistical properties of reconstructed single photon emission computed tomography (SPECT) and positron emission tomography (PET) images would be helpful for optimizing acquisition and image processing protocols. We describe a non-parametric bootstrap approach to accurately estimate the statistical properties of SPECT or PET images whatever the noise properties in the projectio...

متن کامل

Optimization, evaluation, and comparison of standard algorithms for image reconstruction with the VIP-PET

A novel positron emission tomography (PET) scanner design based on a room-temperature pixelated CdTe solid-state detector is being developed within the framework of the Voxel Imaging PET (VIP) Pathfinder project [1]. The simulation results show a great potential of the VIP to produce high-resolution images even in extremely challenging conditions such as the screening of a human head [2]. With ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of nuclear medicine

دوره 20 3  شماره 

صفحات  -

تاریخ انتشار 2006