Protrusion of hardware impairs forearm rotation after olecranon fixation. A report of two cases.

نویسندگان

  • Felix Matthews
  • Otmar Trentz
  • Augustinus Ludwig Jacob
  • Ron Kikinis
  • Jesse B Jupiter
  • Peter Messmer
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Management of heterotopic ossification and restricted forearm rotation after tension band wiring for olecranon fracture

A 32-year-old lady presented to our clinic with persistent painful restriction of her dominant forearm movements for three months after tension band wiring of olecranon. She had full elbow flexion and extension; however, her forearm rotations were restricted and painful. Investigations revealed prominent tips of the wire, eroding the radial tuberosity with heterotopic ossification between the r...

متن کامل

Cementless Total Hip Arthroplasty After an Iatrogenic Subtrochanteric Fracture due to Hardware Removal: A Case Report

Introduction: Total hip arthroplasty (THA) after proximal femoral fixation is a challenging procedure due to possible hardware-related complications. Case presentation: A 78-year-old female with hip osteoarthritis had a proximal femoral osteotomy fixed using a blade plate in the same femur 41 years ago. A two-step approach was planned. After a challenging...

متن کامل

Results of Closed Intramedullary Nailing using Talwarkar Square Nail in Adult Forearm Fractures.

ABSTRACT The aim of the study was to evaluate results of closed intramedullary nailing using Talwarkar square nails in adult forearm fractures. We prospectively evaluated 34 patients with both bone forearm fractures. The average time to union was 12.8 (SD +3.2) weeks with cast support for a mean of 8.2 weeks. Union was achieved in 31 out of 34 patients. Using the Grace and Eversmann rating syst...

متن کامل

Malpositioned olecranon fracture tension-band wiring results in proximal radioulnar synostosis

BACKGROUND Tension-band wiring (TBW) is a well-established fixation technique for two-part, transverse fracture types of the olecranon. However, complication rates up to 80 % are reported. By reporting on the enormous impact on the patient if failed the aim of the present report was to emphasize the importance of correct K wire positioning in TBW. CASE PRESENTATION We present the case of a 49...

متن کامل

Use of Ilizarov Fixator for Grade III B Open Olecranon Fracture: a Case Report and Surgical Technique

INTRODUCTION External fixator application can be difficult for olecranon fractures in presence of large degloving injuries. We describe use of simple Ilizarov ring fixator construct for grade IIIB open olecranon fracture management. CASE REPORT A 45-year-old female with Grade III B open comminuted olecranon fracture (30*15cm degloving area) and ulnar nerve palsy was treated with a novel ring ...