Frequency analysis of the wavefront-coding odd-symmetric quadratic phase mask.

نویسندگان

  • Manjunath Somayaji
  • Marc P Christensen
چکیده

A mathematical analysis of the frequency response of the wavefront-coding odd-symmetric quadratic phase mask is presented. An exact solution for the optical transfer function of a wavefront-coding imager using this type of mask is derived from first principles, whose result applies over all misfocus values. The misfocus-dependent spatial filtering property of this imager is described. The available spatial frequency bandwidth for a given misfocus condition is quantified. A special imaging condition that yields an increased dynamic range is identified.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving photon count and flat profiles of multiplex imaging systems with the odd-symmetric quadratic phase modulation mask.

The odd-symmetric quadratic (OSQ) phase mask is examined as a candidate for reduction of working distance and enhancement of light collection in multiplex imaging systems. The knowledge gained from the exact mathematical representation of the optical transfer function of the OSQ phase mask imager is exploited to explain the limits of system performance and quantify the upper bound on the magnit...

متن کامل

Decomposition of the OTF: Wavefront Coding as a Cornu Spiral

Recent years have witnessed the development of a new imaging technique, known as wavefront coding, that employs an aspherical phase mask and post-detection electronic processing to enable high-performance imaging with far greater tolerance to defocus aberration than traditional optical imaging [1]. Various methods have been employed for synthesizing the design of wavefront-coding phase mask [1,...

متن کامل

Reducing depth induced spherical aberration in 3D widefield fluorescence microscopy by wavefront coding using the SQUBIC phase mask

Imaging thick biological samples introduces spherical aberration (SA) due to refractive index (RI) mismatch between specimen and imaging lens immersion medium. SA increases with the increase of either depth or RI mismatch. Therefore, it is difficult to find a static compensator for SA. Different wavefront coding methods have been studied to find an optimal way of static wavefront correction to ...

متن کامل

Wavefront Coding for Athermalization of Infrared Imaging Systems

Wavefront coding involves the insertion of an asymmetric refractive mask close to the pupil plane of an imaging system so as to encode the image with a specific point spread function that, when combined with decoding of the recorded image, can enable greatly reduced sensitivity to imaging aberrations. The application of wavefront coding has potential in the fields of microscopy, where increased...

متن کامل

Use of a Two-Channel Moiré Wavefront Sensor for Measuring Topological Charge Sign of the Vortex Beam and Investigation of Its Change Due to an Odd Number of Reflections

One of the solutions of the Helmholtz equation is the vortex beams. In the recent decades, production and applications of these types of beams have found serious attentions. Determination of the vortex beam topological charge and its sign are very important issues. Odd number of reflections of the vortex beam changes its vorticity. In this paper, we have used a q-plate to generate a vortex beam...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Applied optics

دوره 46 2  شماره 

صفحات  -

تاریخ انتشار 2007