Long-wavelength optical coherence tomography at 1.7 microm for enhanced imaging depth.

نویسندگان

  • Utkarsh Sharma
  • Ernest W Chang
  • Seok H Yun
چکیده

Multiple scattering in a sample presents a significant limitation to achieve meaningful structural information at deeper penetration depths in optical coherence tomography (OCT). Previous studies suggest that the spectral region around 1.7 microm may exhibit reduced scattering coefficients in biological tissues compared to the widely used wavelengths around 1.3 mum. To investigate this long-wavelength region, we developed a wavelength-swept laser at 1.7 microm wavelength and conducted OCT or optical frequency domain imaging (OFDI) for the first time in this spectral range. The constructed laser is capable of providing a wide tuning range from 1.59 to 1.75 microm over 160 nm. When the laser was operated with a reduced tuning range over 95 nm at a repetition rate of 10.9 kHz and an average output power of 12.3 mW, the OFDI imaging system exhibited a sensitivity of about 100 dB and axial and lateral resolution of 24 mum and 14 mum, respectively. We imaged several phantom and biological samples using 1.3 mum and 1.7 microm OFDI systems and found that the depth-dependent signal decay rate is substantially lower at 1.7 microm wavelength in most, if not all samples. Our results suggest that this imaging window may offer an advantage over shorter wavelengths by increasing the penetration depths as well as enhancing image contrast at deeper penetration depths where otherwise multiple scattered photons dominate over ballistic photons.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal wavelength for ultrahigh-resolution optical coherence tomography.

The influence of depth dependent dispersion by the main component of biological tissues, water, on the resolution of OCT was studied. Investigations showed that it was possible to eliminate the influence of depth dependent dispersion by water in tissue by choosing a light source with a center wavelength near 1.0 microm. Ultrahigh resolution ophthalmic imaging was performed at this wavelength ra...

متن کامل

Cellular resolution ex vivo imaging of gastrointestinal tissues with optical coherence microscopy.

Optical coherence microscopy (OCM) combines confocal microscopy and optical coherence tomography (OCT) to improve imaging depth and contrast, enabling cellular imaging in human tissues. We aim to investigate OCM for ex vivo imaging of upper and lower gastrointestinal tract tissues, to establish correlations between OCM imaging and histology, and to provide a baseline for future endoscopic studi...

متن کامل

Development of a high power supercontinuum source in the 1.7 μm wavelength region for highly penetrative ultrahigh-resolution optical coherence tomography.

We developed a high power supercontinuum source at a center wavelength of 1.7 μm to demonstrate highly penetrative ultrahigh-resolution optical coherence tomography (UHR-OCT). A single-wall carbon nanotube dispersed in polyimide film was used as a transparent saturable absorber in the cavity configuration and a high-repetition-rate ultrashort-pulse fiber laser was realized. The developed SC sou...

متن کامل

High-resolution three-dimensional optical coherence tomography imaging of kidney microanatomy ex vivo.

Optical coherence tomography (OCT) is an emerging medical imaging technology that enables high-resolution, noninvasive, cross-sectional imaging of microstructure in biological tissues in situ and in real time. When combined with small-diameter catheters or needle probes, OCT offers a practical tool for the minimally invasive imaging of living tissue morphology. We evaluate the ability of OCT to...

متن کامل

High-speed spectral-domain optical coherence tomography at 1.3 mum wavelength.

We demonstrate a high-speed spectral domain optical coherence tomography (SD-OCT) system capable of acquiring individual axial scans in 24.4 micros at a rate of 19,000 axial scans per second, using an InGaAs line scan camera and broadband light source centered at 1.31microm. Sensitivity of >105 dB over a 2-mm depth range was obtained with a free-space axial resolution of 12-14 microm, in agreem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics express

دوره 16 24  شماره 

صفحات  -

تاریخ انتشار 2008