Ventilation Rates and Airflow Pathways in Patient Rooms: A Case Study of Bioaerosol Containment and Removal.
نویسندگان
چکیده
Most studies on the transmission of infectious airborne disease have focused on patient room air changes per hour (ACH) and how ACH provides pathogen dilution and removal. The logical but mostly unproven premise is that greater air change rates reduce the concentration of infectious particles and thus, the probability of airborne disease transmission. Recently, a growing body of research suggests pathways between pathogenic source (patient) and control (exhaust) may be the dominant environmental factor. While increases in airborne disease transmission have been associated with ventilation rates below 2 ACH, comparatively less data are available to quantify the benefits of higher air change rates in clinical spaces. As a result, a series of tests were conducted in an actual hospital to observe the containment and removal of respirable aerosols (0.5-10 µm) with respect to ventilation rate and directional airflow in a general patient room, and, an airborne infectious isolation room. Higher ventilation rates were not found to be proportionately effective in reducing aerosol concentrations. Specifically, increasing mechanical ventilation from 2.5 to 5.5 ACH reduced aerosol concentrations only 30% on average. However, particle concentrations were more than 40% higher in pathways between the source and exhaust as was the suspension and migration of larger particles (3-10 µm) throughout the patient room(s). Computational analyses were used to validate the experimental results, and, to further quantify the effect of ventilation rate on exhaust and deposition removal in patient rooms as well as other particle transport phenomena.
منابع مشابه
تنوع و تراکم بیوآئروسولهای اتاقهای عمل بیمارستانهای آموزشی همدان و اثربخشی سیستم های تهویه
Introduction & Objective: The bioaerosol is one of the operating room(OR) hazards that can be threaten of personel health and capable to creating of postoperetive infection in the patients. Because of the hospital infection rate has correleted to bioaerosol concentration, therefore, it is important to determine of type and concentration of these microorganisms as the main goal of this study. ...
متن کاملارزیابی کیفیت هوا در بخش های مختلف یک بیمارستان در شهر قزوین
Introduction Hundreds of millions of patients are affected by nosocomial infections worldwide each year, leading to significant mortality and financial losses for health systems. Maintenance of adequate indoor air quality Air (IAQ) at hospitals is critical to the prevention of these infections. Evaluation of IAQ can be performed by bioaerosol sampling and particle counting. The current study a...
متن کاملImpact of positive pressure ventilation on thoracostomy tube removal in traumatic patients who admitted in ICU
Introduction: Few studies is in literature related to evaluation of impact of positive pressure ventilation (PPV) on thoracostomy tube removal in Iran. We decided, in this study, to evaluate the impact of PPV on recurrent pneumothorax (PTX) after removal of thoracostomy tubes (TT). Methods: A case-control study was performed for evaluating 122 chest tubes in 109 mechanically ventilatedtrauma pa...
متن کاملModeling environmental contamination in hospital single‐ and four‐bed rooms
UNLABELLED Aerial dispersion of pathogens is recognized as a potential transmission route for hospital acquired infections; however, little is known about the link between healthcare worker (HCW) contacts' with contaminated surfaces, the transmission of infections and hospital room design. We combine computational fluid dynamics (CFD) simulations of bioaerosol deposition with a validated probab...
متن کاملThe ventilation of multiple-bed hospital wards: review and analysis.
BACKGROUND Although the merits of ventilating operating theatres and isolation rooms are well known, the clinical benefits derived from ventilating hospital wards and patient rooms are unclear. This is because relatively little research work has been done in the ventilation of these areas compared with that done in operating theatres and isolation rooms. Consequently, there is a paucity of good...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Annals of occupational hygiene
دوره 59 9 شماره
صفحات -
تاریخ انتشار 2015