High-density small-volume gel loading directly from capillary tubes.
نویسندگان
چکیده
A technique has been developed for high lane density loading of small-volume DNA samples in a horizontal agarose gel. This technique has been investigated with a simple hand-held tool that is made to couple to sample output from a new capillary-based sample automation system. The approach consists of piercing the gel with pressurized sample capillaries and relieving the pressure shortly before withdrawal. The pressurization prevents the capillary from aspirating the gel buffer and keeps the sample at the tip of the capillary, so that it may be sucked into the gel during withdrawal. This method is shown to be adequate for a wide range of DNA ladders and PCR-based screening. In addition to allowing smaller lanes and a higher lane density than is achievable with traditional well-forming techniques, it relaxes the need for well formation and the alignment of the sample loader with those wells, providing an easy, efficient means of loading agarose gels.
منابع مشابه
Evaluation of small-volume tubes for venous and capillary PT (INR) samples.
INTRODUCTION Frequent PT (INR) testing may represent a problem for patients on warfarin treatment, and capillary or small-volume tubes may be more appropriate for such patients. A demand for small-volume tubes also comes from pediatric wards. Yet, while various small-volume tubes are available, they have not been properly evaluated. METHODS Three small-volume tubes were tested (MiniCollect 3....
متن کاملNanoliter sample handling combined with microspot MALDI-MS for detection of gel-separated phosphoproteins.
We describe a microspot matrix-assisted laser desorption ionization (MALDI) mass spectrometric approach to analyze gel-separated phosphoproteins. This method involves in-gel digestion of phosphoproteins after gel separation, followed by open tubular capillary (OTC) immobilized metal-ion affinity chromatography (IMAC) to capture the phosphopeptides with markedly reduced interferences from nonpho...
متن کاملSuspended microchannel resonators for ultralow volume universal detection.
Universal detectors that maintain high sensitivity as the detection volume is reduced to the subnanoliter scale can enhance the utility of miniaturized total analysis systems (mu-TAS). Here the unique scaling properties of the suspended microchannel resonator (SMR) are exploited to show universal detection in a 10 pL analysis volume with a density detection limit of approximately 1 microg/cm (3...
متن کاملGel protein capillary extraction apparatus. electronic protein transfer.
A gel protein capillary extraction apparatus is developed and demonstrated for its rapid and effective transfer of SDS-protein complexes from polyacrylamide gel to a fused-silica capillary. The small dimensions of capillary columns permit the application of high voltages for achieving rapid and effective transfer of gel proteins. Furthermore, the fused-silica capillaries are internally coated w...
متن کاملCharacterization of Liquid Bridge in Gas/Oil Gravity Drainage in Fractured Reservoirs
Gravity drainage is the main mechanism which controls the oil recovery from fractured reservoirs in both gas-cap drive and gas injection processes. The liquid bridge formed between two adjacent matrix blocks is responsible for capillary continuity phenomenon. The accurate determination of gas-liquid interface profile of liquid bridge is crucial to predict fracture capillary pressure precisely. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- BioTechniques
دوره 27 5 شماره
صفحات -
تاریخ انتشار 1999