Amniotic fluid fluorescence polarisation values for assessing fetal lung maturation.
نویسندگان
چکیده
The fluorescence probe 1,6, diphenyl-1,3,5-hexatriene was used to determine the micro-viscosity of third trimester amniotic fluid samples utilising an Aminco Bowman spectrofluorometer fitted with a polariser prism. The results were related to the lecithin sphingomyelin (L:S) ratio. A fluorescence polarisation value of 0.360 corresponded to an L:S ratio of 2.0 in uncomplicated and diabetic pregnancies. Pregnancies complicated by Rhesus disease gave significantly different fluorescence polarisation values when compared with the uncomplicated pregnancies.
منابع مشابه
Fluorometric procedure for determining "lamellar body" phospholipids in the particulate fraction of amniotic fluid after filtration.
A rapid (30-min) semiautomated continuous-flow procedure is described for use in assessing the phospholipids of the particulate ("lamellar body") fraction of human amniotic fluid. The method is based on measuring the difference in fluorescence of 1,6,-diphenyl-1,3,5-hexatriene added to amniotic fluid before and after micropore filtration. The filtration step removes "lamellar body" particles, w...
متن کاملImproved fluorescence polarization assay for use in evaluating fetal lung maturity. II. Analytical evaluation and comparison with the lecithin/sphingomyelin ratio.
We assessed the analytical performance of an improved fluorescence polarization assay for use in evaluating fetal lung maturity and compared results with the lecithin/sphingomyelin ratio. During a three-month period 150 patients' samples were assayed by clinical laboratory personnel with both techniques. Values for the lecithin/sphingomyelin ratio correlate closely with net fluorescence polariz...
متن کاملCaesarean section at term: the relationship between neonatal respiratory morbidity and microviscosity in amniotic fluid.
OBJECTIVES The incidence of neonatal respiratory morbidity following an elective caesarean section is 2-3 times higher than after a vaginal delivery. The microviscosity of surfactant phospholipids, as measured with fluorescence polarisation, is linked with the functional characteristics of fetal surfactant and thus fetal lung maturity, but so far this point has received little attention in newb...
متن کاملAmniotic fluid polarization of fluorescence and lecithin/sphingomyelin ratio decision criteria assessed.
A negative finding of amniotic fluid (AF) phosphatidyl glycerol (PG) does not eliminate the need for determining the lecithin/sphingomyelin ratio (LSR). We use a novel approach to classify fetal lung maturity (FLM) data, and to validate the fluorescence polarization (FP) surfactant assay (Abbott), which replaces the PG assay and reduces the frequency of repeat LSR. This method finds the values ...
متن کاملProspective clinical evaluation of an improved fluorescence polarization assay for predicting fetal lung maturity.
We performed a prospective clinical evaluation of our newly developed fluorescence polarization procedure to predict fetal lung maturity (Clin Chem 1986;32:248-54). Net fluorescence polarization was measured at 34 degrees C after a 6.5-min incubation of amniotic fluid with fluorophore. For the 26 cases of neonatal respiratory distress syndrome encountered in 196 deliveries, the net polarization...