Temperature Calibration of Differential Scanning Calorimeters

نویسنده

  • D. M. Price
چکیده

A procedure for calibrating the temperature scale of a DSC is described. A different calibration trend was obtained using the transition points of organic compounds compared to that found using the melting points of highly pure metals. The crystal-crystal transitions of three ammonium salts were studied by this method; ammonium dihydrogen phosphate and ammonium sulphate were found to be suitable reference materials in the region -150 to 0°C, but ammonium nitrate was found to be unsuitable due to poorly defined transition points and inconsistent thermal behaviour.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization of cationic vector-based gene delivery vehicles using isothermal titration and differential scanning calorimetry.

Within the past 10 years, major advances in the design and development of differential scanning calorimeters (DSC) (1) and isothermal titration calorimeters (ITC) (2) have resulted in an unparalleled level of sensitivity, stability, and reproducibility in calorimetric measurements of large molecules. These improvements have allowed the thermal stability and ligand binding processes of biologica...

متن کامل

Thermal hazard analysis of styrene monomer at Low temperature conditions during storage and transportation

Distributed Multimedia Information System Laboratory School of Computer Science, Florida International University Miami, FL 33199, USA Abstract Styrene Monomer (SM) has been widely used for producing polystyrene (PS), acrylonitrile-butadiene-styrene (ABS) and styrene-acryonitrile (SAN) in the petrochemical industry. From 1994 to 2001, several serious accidents occurred in Taiwan due to styrene ...

متن کامل

Energy-calibration of the Atlas Hadronic and Electromagnetic Liquid-argon Endcap Calorimeters

In 2002 the first combined beam test of the hadronic and electromagnetic liquidargon endcap calorimeters of the ATLAS experiment took place at the SPS test beam at CERN. A total of 15 million events from electrons, muons and pions in the energy range from 6 to 200GeV were recorded. The entire calibration chain, from digital filter weights, over calibration constants, to clustering and energy we...

متن کامل

A new in situ electrical calibration system for high temperature Calvet calorimeters.

A new in situ high temperature electrical calibration system was developed at Laboratoire National de Metrologie et d'Essais, Laboratoire Commun de Metrologie and integrated into a heat flux Calvet calorimeter in order to perform accurate and reliable measurements of enthalpy of fusion that are directly traceable to the International System of Units (SI). This system has been designed to enable...

متن کامل

Heat capacity measurements of Sn nanostructures using a thin-film differential scanning calorimeter with 0.2 nJ sensitivity

We have developed a new thin-film differential scanning calorimetry technique that has extremely high sensitivity of 0.2 nJ. By combining two calorimeters in a differential measurement configuration, we have measured the heat capacity and melting process of Sn nanostructures formed via thermal evaporation with deposition thickness down to 1 Å. The equivalent resolution of the calorimeter is 1 n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999